Products
-
Flow, Humidity and Temperature Hand-Held Measuring Unit HND-F115
| For weight moisture or relative humidity |
| Measuring range | 0(4) -100 % rel. humidity |
| Accuracy | ± 0,1 / 0,2 % of rel.humidity |
| Supply | 9 V battery |
| Holding Function, min/max. -memory, alarm, |
| data logger, output 0-1 V, RS 232 |
| Option | temperature-, flow measuring |
-
Precision Hand-Held Thermometer HND-T125
| Measuring range | -65... +199,9°C, -65..+1150°C |
| Probe | Thermo couples K |
| Accuracy | ± 0,05 %, ±0,1 % of m. value |
| Supply | 9 V battery |
| Holding Function, min/max. -memory, °C/°F |
-
Humidity/temperature Measuring Instrument AFH-G
| Operating temperature | -30...+80 °C |
| umidity | 30..100 % RH |
| Probe | polymer fibre inside st. st. housing, 220 mm |
| Max. pressure | pressureless |
| Max. temperature | -20...60 °C (housing), |
| -40..+80 °C (sensor) |
| Accuracy of temperature | ±0, 5 °C |
| humidity | ± 2,5 % RH (<40% RH |
| Output | temperature |
| humidity | 100-138,5 Ohm or 4-20 mA |
-
Humidity/ Temperature Measuring Instrument (capacitive) AFK-G
| Operating range | temperature |
| humidity | 0... 100 % RH |
| Max. pressure | 25 bar |
| Max. temperature | +200 °C |
| Accuracy of temperature | ±0,1 °C |
| humidity | ± 2 %RH |
| Output | 2 x 4-20 mA |
-
Humidity Annex Switch AFS-G3
| Operating range | 50 - 100 % RH |
| Max. pressure | pressureless |
| Max. temperature | 0...60 °C |
| Accuracy | ± 3 %RH |
| Contact | 1 micro switch, adjustable from inside |
-
Hand-Held pH, Redox, Temperature Measuring Unit HND-R
| Measuring range | |
| pH | 0,00 ...14,00 |
| Redox | -1999 mV...+2000 mV |
| Temperature | -100,0...+250,0 °C |
| Accuracy | ± 0,01 pH, ± 0,1 % FS (mV), ± 0,2 (0,4) °C. |
| Supply | 9 V battery |
| hold function, min/max. -memory |
-
Inductive Conductivity / Concentration and Temperature Transmitter LCI
| Measuring range | 0-500 µS/cm...0-2000 mS/cm |
| Connection | G 1 ¼ AG - 2 AG, screwed pipe conn. DIN 11851, Tri-Clamp®, Varivent® |
| Material | PEEK. PVDF |
| Max.pressure | 10 bar |
| Max. temperature | 120 °C (short term 140 °C) |
| Accuracy | 1 % |
-
Turbidity Meter ATL
| Measuring range | 0...3 CU |
| Connections | DIN-/ ANSI-flange, NPT, BSP thread, hygenic connection |
| Material | st. st. |
| Max. pressure | 10 bar |
| Max. temperature | 0...100°C |
| Output | 4...20 mA, 2 limit switches |