Products

  • Hand-Held Conductivity Measuring Unit HND-C
    Measuring range
    conductivity 0,0...200.0 mikroS up to 0,0...200.0 mS
    temperature -5,0...+100,0 °C
    Accuracy
    conductivity ± 0,5v. MV, /± 0,3 % v. FS
    temperature ± 0,2 % v. MV ± 0,3 K
    Supply 9 V battery
    Hold function, min/max. -memory
    Output RS 232 or USB
  • Inductive Conductivity / Concentration and Temperature Transmitter LCI
    Measuring range 0-500 µS/cm...0-2000 mS/cm
    Connection G 1 ¼ AG - 2 AG, screwed pipe conn. DIN 11851, Tri-Clamp®, Varivent®
    Material PEEK. PVDF
    Max.pressure 10 bar
    Max. temperature 120 °C (short term 140 °C)
    Accuracy 1 %
  • Universal Bussystem KOBUS
    as plug-on display, 4-digit, red LED
    up to 240 sensors, BUS-length max. 1km
    for transmitters with (0)4-20 mA, 0-10 V or
    0.5..1000 Hz output and plug DIN 43 650
    software for indication, datalogger, configuration
  • Flow, Humidity and Temperature Hand-Held Measuring Unit HND-F115
    For weight moisture or relative humidity
    Measuring range 0(4) -100 % rel. humidity
    Accuracy ± 0,1 / 0,2 % of rel.humidity
    Supply 9 V battery
    Holding Function, min/max. -memory, alarm,
    data logger, output 0-1 V, RS 232
    Option temperature-, flow measuring
  • Humidity/temperature Measuring Instrument AFH-G
    Operating temperature -30...+80 °C
    umidity 30..100 % RH
    Probe polymer fibre inside st. st. housing, 220 mm
    Max. pressure pressureless
    Max. temperature -20...60 °C (housing),
    -40..+80 °C (sensor)
    Accuracy of temperature ±0, 5 °C
    humidity ± 2,5 % RH (<40% RH
    Output temperature
    humidity 100-138,5 Ohm or 4-20 mA
  • Humidity/ Temperature Measuring Instrument (capacitive) AFK-G
    Operating range temperature
    humidity 0... 100 % RH
    Max. pressure 25 bar
    Max. temperature +200 °C
    Accuracy of temperature ±0,1 °C
    humidity ± 2 %RH
    Output 2 x 4-20 mA
  • Humidity Measuring Instrument with Indicator (capacitive) AFA-G
    Operating range 0 - 100 % RH
    Max. pressure pressureless
    Max. temperature 0...60 °C
    Accuracy ± 2 % RH (5...95 % RH)
    output 4-20 mA
    Plug-on display 3,5-digit LED
    Option limit switch
  • Hygrostat AFS-G1
    Operating range 35 - 100 % RH
    Probe polymere fibres inside st. st. housing, 220 mm
    Max. pressure pressureless
    Max. temperature -30...60 °C
    Accuracy ± 3,5 % RH (<50%RH
    Contact 1 micro switch
  • Room Hygrostat AFS-G2
    Operating range 35 - 100 % RH
    Max. pressure pressureless
    Max. temperature 0...60 °C
    Accuracy ± 3 % RH
    Contact 1 micro switch, adjustable
  • Humidity Annex Switch AFS-G3
    Operating range 50 - 100 % RH
    Max. pressure pressureless
    Max. temperature 0...60 °C
    Accuracy ± 3 %RH
    Contact 1 micro switch, adjustable from inside
  • Turbidity Meter ATA-K
    Absorbtion method (infrared)
    Measuring range 0...4 CU
    Connections DIN-/ ANSI-flange, NPT, BSP-thread, hygenic connection
    Material st. st.
    Max. pressure 16 bar
    Max. temperature 0...10°C (short-time 120°C)
    Measuring Accuracy +/-2% FS
    Output 4...20 mA, 2 limit switches
  • Turbidity Meter ATS-K
    Dual Light Scattering-method (11°)
    Measuring range 0...500 ppm
    Connections DIN-/ ANSI-flange, NPT, BSP thread, hygenic connection
    Material st. st.
    Max. pressure 16 bar
    Max. temperature 0...190°C
    Measuring Accuracy +/- 2% FS
    Output 4...20 mA, 2 limit switches
  • Turbidity Meter ATL
    Measuring range 0...3 CU
    Connections DIN-/ ANSI-flange, NPT, BSP thread, hygenic connection
    Material st. st.
    Max. pressure 10 bar
    Max. temperature 0...100°C
    Output 4...20 mA, 2 limit switches