Products
-
Hand-Held Conductivity Measuring Unit HND-C
Measuring range conductivity 0,0...200.0 mikroS up to 0,0...200.0 mS temperature -5,0...+100,0 °C Accuracy conductivity ± 0,5v. MV, /± 0,3 % v. FS temperature ± 0,2 % v. MV ± 0,3 K Supply 9 V battery Hold function, min/max. -memory Output RS 232 or USB
-
Inductive Conductivity / Concentration and Temperature Transmitter LCI
Measuring range 0-500 µS/cm...0-2000 mS/cm Connection G 1 ¼ AG - 2 AG, screwed pipe conn. DIN 11851, Tri-Clamp®, Varivent® Material PEEK. PVDF Max.pressure 10 bar Max. temperature 120 °C (short term 140 °C) Accuracy 1 %
-
Universal Bussystem KOBUS
as plug-on display, 4-digit, red LED up to 240 sensors, BUS-length max. 1km for transmitters with (0)4-20 mA, 0-10 V or 0.5..1000 Hz output and plug DIN 43 650 software for indication, datalogger, configuration
-
Flow, Humidity and Temperature Hand-Held Measuring Unit HND-F115
For weight moisture or relative humidity Measuring range 0(4) -100 % rel. humidity Accuracy ± 0,1 / 0,2 % of rel.humidity Supply 9 V battery Holding Function, min/max. -memory, alarm, data logger, output 0-1 V, RS 232 Option temperature-, flow measuring
-
Humidity/temperature Measuring Instrument AFH-G
Operating temperature -30...+80 °C umidity 30..100 % RH Probe polymer fibre inside st. st. housing, 220 mm Max. pressure pressureless Max. temperature -20...60 °C (housing), -40..+80 °C (sensor) Accuracy of temperature ±0, 5 °C humidity ± 2,5 % RH (<40% RH Output temperature humidity 100-138,5 Ohm or 4-20 mA
-
Humidity/ Temperature Measuring Instrument (capacitive) AFK-G
Operating range temperature humidity 0... 100 % RH Max. pressure 25 bar Max. temperature +200 °C Accuracy of temperature ±0,1 °C humidity ± 2 %RH Output 2 x 4-20 mA
-
Humidity Measuring Instrument with Indicator (capacitive) AFA-G
Operating range 0 - 100 % RH Max. pressure pressureless Max. temperature 0...60 °C Accuracy ± 2 % RH (5...95 % RH) output 4-20 mA Plug-on display 3,5-digit LED Option limit switch
-
Hygrostat AFS-G1
Operating range 35 - 100 % RH Probe polymere fibres inside st. st. housing, 220 mm Max. pressure pressureless Max. temperature -30...60 °C Accuracy ± 3,5 % RH (<50%RH Contact 1 micro switch
-
Room Hygrostat AFS-G2
Operating range 35 - 100 % RH Max. pressure pressureless Max. temperature 0...60 °C Accuracy ± 3 % RH Contact 1 micro switch, adjustable
-
Humidity Annex Switch AFS-G3
Operating range 50 - 100 % RH Max. pressure pressureless Max. temperature 0...60 °C Accuracy ± 3 %RH Contact 1 micro switch, adjustable from inside
-
Turbidity Meter ATA-K
Absorbtion method (infrared) Measuring range 0...4 CU Connections DIN-/ ANSI-flange, NPT, BSP-thread, hygenic connection Material st. st. Max. pressure 16 bar Max. temperature 0...10°C (short-time 120°C) Measuring Accuracy +/-2% FS Output 4...20 mA, 2 limit switches
-
Turbidity Meter ATS-K
Dual Light Scattering-method (11°) Measuring range 0...500 ppm Connections DIN-/ ANSI-flange, NPT, BSP thread, hygenic connection Material st. st. Max. pressure 16 bar Max. temperature 0...190°C Measuring Accuracy +/- 2% FS Output 4...20 mA, 2 limit switches
-
Turbidity Meter ATL
Measuring range 0...3 CU Connections DIN-/ ANSI-flange, NPT, BSP thread, hygenic connection Material st. st. Max. pressure 10 bar Max. temperature 0...100°C Output 4...20 mA, 2 limit switches