Products
-
Universal Bussystem KOBUS
| as plug-on display, 4-digit, red LED |
| up to 240 sensors, BUS-length max. 1km |
| for transmitters with (0)4-20 mA, 0-10 V or |
| 0.5..1000 Hz output and plug DIN 43 650 |
| software for indication, datalogger, configuration |
-
Calorimetric Indicator/Switch KAL, KAL-E
| Sensor and Electronic seperate |
| Switching range | 4 cm/s ... 2 m/s |
| Connection | G ¼... G 11/2, ¼ NPT...1 ½ NPT |
| Material | brass, st. st. |
| Max. pressure | 100 bar |
| Max. temperature | 80 (120) °C |
| Repeatability | approx. 2 % |
| Relays for flow and temperature |
| Option | Ex II(1)G[EExia] II B T4 |
-
Mass-Flowmeter-Thermal DMW-A/B
| Measuring range | 0,005-0,1...300-6000 NL/min air |
| Connection | pipe connection G ¼...G1 |
| Material | aluminum, st. st. |
| Max. pressure | 10 bar |
| Max. temperature | 50 °C |
| Accuracy | ± 3 % FS |
| Analogue output, option | LC display, totalizer |
-
Vortex Flowmeter PWL
| Measuring range | liquids 0,15 - 4,92 ...13,5-544 m³/h |
| gas/vapour 3-23 ... 413-4855 m³/h |
| Connection | flange DN 15... DN 300 |
| wafer DN15...DN150 |
| Material | st. st. |
| Max. pressure | PN 40 |
| Max. temperature | 400 °C |
| Accuracy | liquids <0,75% of m. value (Re >20000) |
| gas/vapour <1 % of m. value (Re >20000) |
| analogue output, digital display |
-
Calorimetric Indicator/Switch KAL-K
| Switching range | 4 cm/s ... 2 m/s |
| Connection | G ¼...G 3/4, ¼ NPT...¾ NPT, M12x1, Tri Clamp |
| Material | st. st. |
| Max. pressure | 100 bar |
| Max. temperature | 80 °C |
| Repeatability | aprox 2 % |
| LED-chain, relays |
-
Calorimetric Flowmeter,-switch DVK
| Range | 1-10...600-12 000 L/min air |
| Connection | G ¼...G 2 |
| Material | connection |
| Max. pressure | 10 bar |
| Max. temperature | 50 °C |
| Accuracy | ± 5% v. ME |
| LED-Indication, 2 open collector PNP, totalizing function |
-
Calorimetric Indicator/Switch KAL-D
| Switching range | 0,04 m/s ... 2 m/s |
| Connection | G ¼, G ½, ¼ NPT, ½ NPT, M12 x 1 |
| Material | stainless steel |
| Pmax | 40 bar ( 140°C CIP, device not in function) |
| Tmax | 80°C |
| Repeatability | +/- 2 % |
| LCD-display, switching output |
-
Oscillation-Meter/Switch DOG-1
| Range | 0,2-20...160-16.000 m³/h air |
| Connection | flange |
| Material | cast steel, steel, stainless steel |
| Pmax | PN40 bar |
| Tmax | 120°C |
| Accuracy | +/- 1.5 % of measured value (air) |
| Pulse & analogue output, |
| digital display for flow measurement and counter |
-
Vortex-Switch DVZ-..S
| Range | 0,5-4,5...10-100 L/min water |
| Connection | G ¼...G 1, ¼...1" NPT |
| Material | connection |
| Max. pressure | 10 bar |
| Max. temperature | 80 °C |
| Accuracy | ± 2,5% v. ME |
| Switchpoint |
-
Mass Flowmeter/Controller-Thermal DMS
| Measuring range | 0-0.01 .... 0-200 NL/min air |
| Connection | 1/4..1/2 F NPT |
| 1/8..1/2, 6,10,12 mm |
| Material | st. st. |
| Max. pressure | 35 bar |
| Max. temperature 50°C |
| Accuracy | ± 1 % FS |
| 2 outputs, | 4-20 and 0-5,0-10,1-5 VDC |
| digital display, regulator function |
-
Mass Flowmeter-Thermal KES
| Measuring range | 0-4.7 .. 0-94 m/s air |
| Connection | plug-in version bis NW1000 |
| 1/4"...8" NPT, DIN-flange DN25..DN200 |
| ANSI-flange | 1"...8" |
| Material | st. st. |
| Max. pressure | 16 bar |
| Max. temperature | 175 °C |
| Accuracy | ± 1 % FS |
| Analogue output, RS 232 |
-
Mass Flowmeter Coriolis TM
| high accuracy and special versions |
| Measuring range | 0,8 - 8 kg/h ... 4.000 -40.000 kg/h |
| Connection | flange DN 10 - DN 100;ANSI ½ -3" |
| JIS, NPT, special acc. customers specification |
| Material | st. st., Hastelloy, Monel, Tantal, |
| Nickel, special materials |
| Max. pressure | PN 40 bar (up to 900 bar on request) |
| Max. temperature | -90... +260 °C |
| Accuracy | (liquids) ± 0,1 (0,05) % of m. value ± zero point-stability |
| (gases) ± 0,15 % of m. value ± zero point-stability |
| Transmitter | Analog-, pulse output, digital display, |
| Hart, Profibus, ATEX,FM,FMC,NEPSI |
-
Mass Flowmeter Coriolis TME
| economical version |
| Measuring range | 20 - 200 kg/h ... 6.000 -60.000 kg/h |
| Connection | flange DN 10 - DN 80;ANSI ½ -3" |
| Material | st. st. (1.4571 oder 1.4404) |
| Max. pressure | PN 40 bar |
| Max. temperature | -40... +180 °C |
| Accuracy | (liquids) ± 0,15 % of m. value ± zero point-stability |
| (gases) ± 0,5 % of m. value ± zero point-stability |
| Analog-, pulse output, digital display, |
| Hart, Profibus, ATEX,FM,FMC,NEPSI |
-
Mass Flowmeter Coriolis TMU
| wide measuring span |
| Measuring range | 0,06 - 0,6 t/h ... 400 -2.200 t/h |
| Connection | flange DN 10 - DN 400;ANSI ½ -16" |
| JIS, NPT, special acc. customers specification |
| Material | st. st. (1.4571 or 1.4404) , Hastelloy C-22 |
| Max. pressure | PN 40 bar (higher on request) |
| Max. temperature | -40... +260 °C |
| Accuracy | (liquids) ± 0,1 (0,15%) % of m. value ± zero point-stability |
| (gases) ± 0,5 % of m. value ± zero point-stability |
| Analog-, pulse output, digital display, |
| Hart, Profibus, ATEX,FM,FMC,NEPSI |
-
Electromagnetic-Insertion PIT
| Measuring range | 1-10 m/s (0,5- 5 m/s st.st.-version) |
| Weldable connection sleeves for DN 150..2000 |
| Material | st. st. (1.4571,1.4404) |
| PTFE or PFA- tube lining up to DN 600 |
| Max. pressure | 16 bar, 40 bar (PTFE, PFA-lining) |
| Max.temperature | |
| -40..100°C, -20..80°C (PVDF) , -40...+150 °C (PFA) |
| Accuracy | ± 1,5 % of m. value plus ± 0,,5 % FS |
| Transmitter | relays, analogue/pulse output, digital display, |
| Hart, Profibus, ATEX, NEPSI |
-
Mass Flowmeter Coriolis TMR
| ideal substitute for oval gear meter |
| Measuring range | 0 - 120.000 kg/h liquids |
| 0- 92.000 Nm³/h air |
| Connection | flange DN 50 - 100, ANSI 1 1/2" |
| Material | st. st., Tantal, Hastelloy, Monel, Zirkon |
| Max. pressure | PN 40 bar /300 lbs |
| Max. temperature | 40... +260 °C |
| Accuracy | ± 0,1 (0,15 %) of m. value ± value ± zero point-stability |
| Transmitter | analogue-, pulse output, digital display, |
| Hart, Profibus, ATEX,FM,FMC,NEPSI |