Products
-
Bypass Level Indicator NBK-03
| Measuring length | Max. 6 meters (if longer |
| Connection | DIN-flange DN 15...DN 32 |
| ANSI-flange 1/2"... 1 1/4" |
| Material | st. st. 1.4571 |
| Max. pressure | PN 100, max. temperature |
| Accuracy transducer | +/- 1 mm |
| Option | transmitter 4-20 mA, contacts |
-
Liquid Level Switch NWS
| For liquids |
| Contact | 1 Electronic switch |
| Connection | G 3/4, G1 male, ¾ NPT, 1 NPT male, |
| TriClamp DIN 32676, hygenic DIN 11851 |
| DIN-flange | DN25, DN50;ANSI-flange |
| Material | st. st. 1.4404 |
| Max. pressure | 45 bar |
| Max.temperature | 130°C (150 °C CIP-cleaning) |
| Viscosity | up to 5000 mm²/s |
-
Conductive Level Switch LNK
| For conductive liquids (>10 mikroS) |
| Electrodes | 1-4 pcs, length |
| Connection | G 1/2, G 1 |
| hygenic mounting system (EHEDG) |
| hygenic DIN 11851, Tri-Clamp, weld on sleeve |
| Material | st.st. 1.4404, Option |
| Max. pressure | 10 bar |
| Max.Temperatur | 100°C (CIP 150 °C) |
| Options | head mounted transmitter f. 1 contact |
-
Conductive Level Switch Compact , LNK-K
| for conductive liquids (>10 mikroS) |
| Electrodes | 4 up to 2000 mm |
| Connection | G ½ |
| hygenic mounting system (EHEDG) |
| hygenic DIN 11851, Tri-Clamp, weld on sleeve |
| Material | st.st. 1.4404, option |
| Max. pressure | 10 bar |
| Max.temperature | 150°C |
| Option | head mounted transmitter f. 1 contact |
-
Microwave Level Switch LNM
| As well for non conductive liquids |
| insensitive to foam and adhesions |
| Connection | G 1/2, M12x1,5; |
| hygenic mounting system (EHEDG) |
| hygenic DIN 11851, Tri-Clamp, weld on sleeve |
| Material | st.st. 1.4404 / PEEK |
| Max. pressure | 10 bar |
| Max. temperature | 100 °C (CIP 150°C) |
| Contact | Open Collector, PNP, 50 mA |
-
Continuous Level Probe LNP
| Potentiometric principle |
| For viscous, pasted, strong adhessive medias |
| Measuring length | 200...2000 mm |
| Connection | G 1, 1" NPT, G1 for hygenic sleeve LZE |
| Material | st.st. 1.4404 / PEEK |
| Max. pressure | 10 bar |
| Max. temperature | 120°C (short time 150 °C) |
| Accuracy | ± 1% FS |
| Output | 4-20 mA |
-
Hygenic Mounting Systems LZE
| EHEDG-and 3A-certified |
| Connection sensor | G 1/2, G 3/4, G1, M12x1,5 |
| Connection prozess | weld on sleeve, ball sleeve, collar sleeve, Triclamp, varivent, clamp |
| Material | st.st. 1.4404 |
| Max. pressure | 10 bar |
| Max. temperature | 250°C |
-
Capacitive Level Limit Switch LNZ
| As well for non conductive liquids |
| sensitive to foam, not for adhesions |
| Connection | G 1/2 |
| hygenic mounting system (EHEDG) |
| hygenic DIN 11851, Tri-Clamp, weld on sleeve |
| Material | st.st. 1.4404 / PEEK |
| Max. pressure | 10 bar |
| Max. temperature | 100 °C (CIP 150°C) |
| Contact | Open Collector, PNP, 200 mA |
-
Vibrating Level Switch SOLIVIB NSV
| For powder, granulate |
| Electrodes | max. 3 m |
| Contact | 1 relay (max. 250 VAC, 1A), 25 VA |
| Connection | G 1 ½ male |
| Material | st. st. 1.4305 (303) |
| Max. pressure | pressureless |
| Max.temperature | 80 °C |
| Power supply | 24, 110, 230 VAC, 18...36 VDC |
| Certificates | ATEX |
-
Capacitive Level Limit Switch for bulks NSC
| Electrodes | max. 3 m, with cable 15 m |
| Contact | 1 relay (max. 250 Vac, 1A) |
| Connection | G 1 male, st. steel |
| Material Electrodes | st. steel with PTFE or |
| steel cable with PP coating |
| Max. pressure | -0,1 bis +0,5 bar |
| Max. temperature | -20...+80 °C |
| Power supply | 24, 110, 230 VAC, 18..36 VDC |
-
Level Modul for Conductive Level Probes, LNR
| for conductive level switches |
| output | 1 PNP |
| power supply | 15...36 VDC |
-
Rotating Vane Level Monitor NIR
| For bulks |
| Contact | 1 micro switch |
| Connection | G 1, G 1 ½ male, roand flange |
| Material | shaft/Rotor |
| Max. pressure | 0,5 bar |
| Max .temperature | 80 °C |