Products
-
Digital Panel Indicators DAG
Programmable, 4-digit LED Dimensions 96x48, 96x24, 72x36, 48x24, Input temperature, frequency, current, voltage output 0(4)-20 mA, 0-10 V Options sensor supply, contacts, min/max.-memory
-
Differential Pressure Gauge PAD
Measuring range 0...41370 kPa Connection ¼ NPT, ½ NPT Housing Material st. st. Accuracy ±0,075% of meas. range
-
Bypass Level Indicator Low Cost NBK-01
Measuring length Max. 6 meters Connection G ½, G 3/4, G1, G11/4 1/2, 3/4, 1, 1 ¼ NPT Material st. st. 1.4301 Max. pressure PN 16, Max. temperature Accuracy transducer +/- 1 mm Option transmitter 4-20 mA, contacts
-
Bypass Level Indicator NBK-03
Measuring length Max. 6 meters (if longer Connection DIN-flange DN 15...DN 32 ANSI-flange 1/2"... 1 1/4" Material st. st. 1.4571 Max. pressure PN 100, max. temperature Accuracy transducer +/- 1 mm Option transmitter 4-20 mA, contacts
-
Diaphragm Level Indicator NPF
Measuring range 0-600...0-6000 mm Wc Connection G ½ AG Material st. st. Max. pressure 1,3 x max. range, max. temperature Accuracy +/- 1,6 % FS Option contacts
-
Magnetostrictive Level Meters NMT
Measuring length 300-4000 mm Connection G 2, 2" NPT AG Material st. st. Max. pressure PN 10, Max. temperature Accuracy +/- 1 mm output 4-20 mA
-
Float Transducer-Reed Chain NM
Measuring length max. 6 meters Connection R 3/8...R 2 DIN-flange DN 50...DN 100 Material st. st., PVC, PPH, PTFE,PE Max. pressure PN 20, Max. temperature Accuracy 0,5 % for L=2 m Output resistor, 4-20 mA
-
Deep-Well Probe NTB
Measuring range 0-1...0-200 mWc Material st. st., cable polyurethane Max. pressure 3x range end, max. temperature Accuracy ± 0,5 % FS
-
Over-Head Level Indicator NBK-04
Measuring length max. 4 m Connection DIN-flange DN 50/65 ANSI-flange 2" / 21/2" Material st. st. 1.4571 (316 TI) Max. pressure PN 16, Max. temperature Accuracy transducer +/- 1 mm Options transmitter 4-20 mA, contacts
-
Ultrasonic Level Meter NUS
Measuring range liquids up to 8 m Solids/bulks up to 3,5 m Connection
-
Universal Indicators ADI-B…F
Indicator bargraph Input current ,voltage, frequency Housing 116x116x123 mm Option analogue-, frequency output, contacts, sensor supply Mounting wall- or pipe mounting
-
Continuous Level Probe LNP
Potentiometric principle For viscous, pasted, strong adhessive medias Measuring length 200...2000 mm Connection G 1, 1" NPT, G1 for hygenic sleeve LZE Material st.st. 1.4404 / PEEK Max. pressure 10 bar Max. temperature 120°C (short time 150 °C) Accuracy ± 1% FS Output 4-20 mA
-
Mini Bypass Level Indicator NBK-M
Measuring length Max. 3 meters Connection DIN-flange DN 10...DN 25 ANSI-flange 1/2"... 1" Material st. st. 1.4571 Max. pressure PN 40/300 lbs, max. temperature Accuracy transducer +/- 1 mm Option transmitter 4-20 mA, contacts
-
Limit contact for Bypass -Meter NBK-R
bistable changeover contact max. temperature 100 °C electr. Connection cable
-
Bypass Level Indicator rope version NBK-19
for open vessels Measuring length Max. 4,8 meters Float PPH or st. steel Max. pressure pressureless, max. temperature Accuracy transducer +/- 1 mm Option transmitter 4-20 mA, contacts, scale
-
Capacitive Level Meter NMC
For liquids Measuring length max. 4 m Connection G 1 male, st. steel or G 2 male, PVDF Material st. steel with PTFE or PVDF coating Max. pressure PN 10 bar Max. temperature 90 °C (125 °C) Power supply 12...35 VDC (Atex 12..30 VDC) analogue output 4-20 mA