Products
-
Transmitters for pH-value APM-Z
| COMPACT-LINE |
| Measuring range | pH -1 up to 14 |
| With panel mounted housing or field mounted housing |
| Display of pH-value and temperature with LEDs |
| analogue actual-value output scaleable |
| 2 relays for control functions (PID) programmable |
| 2 binary inputs |
| 1 binary output (alarm contact or temperature limit contact) |
-
Gel-filled pH-Combined Electrode APS-Z
| COMPACT-LINE |
| Measuring range | pH 0 up to 12 |
| Connection | Pg 13,5 |
| temperature range | -5°C up to +80°C |
| Pressure rating | up to 10 bar |
| Salt | KCl gel filling |
| Diaphragm | ceramic or (PTFE)- ring |
| Temperature sensor | Pt 100 possible |
-
Transmitters for pH-Value and ORP, APM-X
| EXPERT-LINE |
| Measuring range | pH |
| Redox | -1500 up to +1500 |
| With panel mounted housing or field mounted housing |
| Large text LC-Display |
| analogue actual-value output scaleable |
| Alarm relays |
| Two additional relays for use as control contacts |
| two digital inputs |
-
Gel-filled pH-Combined Electrode APS-X1Q
| EXPERT-LINE |
| Measuring range | pH 0 up to 12 |
| Connection | Pg 13,5 |
| temperature range | -5°C up to +80°C |
| Pressure rating | up to 10 bar |
| Salt | KCl gel filling |
| Diaphragm | ceramic or (PTFE)- ring |
| Temperature sensor | Pt 100 possible |
-
pH Electrode with Plastic Sheathing, APS-X5K
| EXPERT-LINE |
| Measuring range | pH 0 up to 11 |
| Connection | NPT 3/4" |
| Shock-proof because of plastic case |
| Temperature range | 0 up to 80°C |
| Pressure rating | up to 7 bar |
| Diaphragm | PTFE (teflon) |
| Temperature sensor | Pt 100 possible |
| Cable | 5 m fixed cable |
-
Transmitter for ORP, ARM-Z
| COMPACT-LINE |
| Measuring range | -1999 up to +1999 mV |
| Withpanel mounted housing or field mounted housing |
| Display of ORP and temperature with LEDs |
| analogue actual-value output scaleable |
| 2 relays for control functions (PID) programmable |
| 2 binary inputs |
| 1 binary output (alarm contact or temperature limit contact) |
-
Gel Filled ORP Electrode, ARS-Z
| COMPACT-LINE |
| Sctive section | platinum or gold |
| Connection | Pg 13,5 |
| temperature range | -10°C up to +90°C |
| Pressure rating | up to 10 bar |
| Salt | KCl gel filling |
| Diaphragm | ceramic or (PTFE)- ring |
| Salt bridge for longer life time |
-
Gel Filled Combined Electrode, ARS-X1Q
| EXPERT-LINE |
| Active section | platinum ring or gold pin |
| Connection | Pg 13,5 |
| temperature range | -15 up to +130°C |
| Pressure rating | up to 6 bar |
| salt | KCl gel filling |
| Diaphragm | PTFE (teflon), ring form |
-
ORP Electrode with Plastic Sheathing, ARS-X5K
| EXPERT-LINE |
| Active section | platinum -ring |
| Connection | NPT 3/4" |
| Shock-proof because of plastic case |
| temperature range | 0 up to 80°C |
| Pressure rating | up to 7 bar |
| Diaphragm | PTFE (teflon) |
| Cable | 5 meters fixed cable |
-
Transmitter for Specific Conductivity, ACM-Z
| COMPACT-LINE |
| 0 up to 200 mS/cm |
| With panel mount housing or field mounting housing |
| Display of conductivity and temperature with LEDs |
| analogue actual-value output scaleable |
| 2 relays for control functions (PID) programmable |
| 2 binary inputs |
| 1 binary output (alarm contact or temperature limit contact) |
-
Conductive Conductivity Measuring Cells, ACS-Z
| COMPACT-LINE |
| Measuring range 1, K=0,01 | 0,05 ... 10 µS/cm |
| Measuring range 2, K=0,1 | 0,5 ... 5000 µS/cm |
| Measuring range 3, K=1,0 | 5 µS/cm ... 100 mS/cm |
| Connection | thread G ¾ A |
| Electrode Material | st. st. 1.4571 bzw. graphite |
| temperature range | up to 135°C (at 1 bar) |
| Pressure rating | up to 16 bar (at 25°C) |
| Temperature sensor | Pt 100 integrated |
-
Transmitter for Specific Conductivity, ACM-X
| EXPERT-LINE |
| Measuring range | conductivity |
| resistance | 0 ... 86 M Ohm cm |
| With panel mounted housing or field mounted housing |
| Large LC-Display for text |
| Analogue actual-value output scaleable |
| Alarm relays |
| Two additional relays for use as control contacts |
| Two digital inputs |
-
Conductive Conductivity Measuring Cells, ACS-X
| EXPERT-LINE |
| Measuring range 1, K=0,01 | 0,04 ... 20 µS/cm |
| Measuring range 2, K=0,1 | 0,1 ... 200 µS/cm |
| Measuring range 3, K=1,0 | 50 ... 500 µS/cm |
| Measuring range 4, K= 1,0 | 10 µS/cm ... 20 mS/cm |
| Connection | NPT ½ " or G1" |
| Electrode Material | st. st. 1.4571 or. graphite |
| Temperature sensor | Pt 100 possible |
-
Inductive Conductivity Measuring Cell ACS-X0I
| EXPERT-LINE |
| Measuring range | 5 µS/cm up to 2000 mS/cm |
| Connection | G3/4" of 1.4571 or 1"NPT of PEEK |
| Material of sensor | PEEK (resistant to chemical attack) |
| temperature range | -20 up to +130°C |
| Pressure rating | up to 16 bar |
| Cable | 5 meters fixed cable |
| Temperature sensor | coated Pt 100 integrated |
-
Accessories for Analysing Devices AZA, AZT, AZM
| Immersion assemblies |
| Flow assemblies |
| Process assemblies |
| Buffer solutions for pH and ORP |
| Calibration solutions for conductivity |
| temperature sensors |
| Wall mounting set for field housing |
| Pipe mounting set for field housing |
-
Hand-Held pH, Redox, Temperature Measuring Unit HND-R
| Measuring range | |
| pH | 0,00 ...14,00 |
| Redox | -1999 mV...+2000 mV |
| Temperature | -100,0...+250,0 °C |
| Accuracy | ± 0,01 pH, ± 0,1 % FS (mV), ± 0,2 (0,4) °C. |
| Supply | 9 V battery |
| hold function, min/max. -memory |