Products

  • Transmitters for pH-value APM-Z
    COMPACT-LINE
    Measuring range pH -1 up to 14
    With panel mounted housing or field mounted housing
    Display of pH-value and temperature with LEDs
    analogue actual-value output scaleable
    2 relays for control functions (PID) programmable
    2 binary inputs
    1 binary output (alarm contact or temperature limit contact)
  • Gel-filled pH-Combined Electrode APS-Z
    COMPACT-LINE
    Measuring range pH 0 up to 12
    Connection Pg 13,5
    temperature range -5°C up to +80°C
    Pressure rating up to 10 bar
    Salt KCl gel filling
    Diaphragm ceramic or (PTFE)- ring
    Temperature sensor Pt 100 possible
  • Transmitters for pH-Value and ORP, APM-X
    EXPERT-LINE
    Measuring range pH
    Redox -1500 up to +1500
    With panel mounted housing or field mounted housing
    Large text LC-Display
    analogue actual-value output scaleable
    Alarm relays
    Two additional relays for use as control contacts
    two digital inputs
  • Gel-filled pH-Combined Electrode APS-X1Q
    EXPERT-LINE
    Measuring range pH 0 up to 12
    Connection Pg 13,5
    temperature range -5°C up to +80°C
    Pressure rating up to 10 bar
    Salt KCl gel filling
    Diaphragm ceramic or (PTFE)- ring
    Temperature sensor Pt 100 possible
  • pH Electrode with Plastic Sheathing, APS-X5K
    EXPERT-LINE
    Measuring range pH 0 up to 11
    Connection NPT 3/4"
    Shock-proof because of plastic case
    Temperature range 0 up to 80°C
    Pressure rating up to 7 bar
    Diaphragm PTFE (teflon)
    Temperature sensor Pt 100 possible
    Cable 5 m fixed cable
  • Transmitter for ORP, ARM-Z
    COMPACT-LINE
    Measuring range -1999 up to +1999 mV
    Withpanel mounted housing or field mounted housing
    Display of ORP and temperature with LEDs
    analogue actual-value output scaleable
    2 relays for control functions (PID) programmable
    2 binary inputs
    1 binary output (alarm contact or temperature limit contact)
  • Gel Filled ORP Electrode, ARS-Z
    COMPACT-LINE
    Sctive section platinum or gold
    Connection Pg 13,5
    temperature range -10°C up to +90°C
    Pressure rating up to 10 bar
    Salt KCl gel filling
    Diaphragm ceramic or (PTFE)- ring
    Salt bridge for longer life time
  • Gel Filled Combined Electrode, ARS-X1Q
    EXPERT-LINE
    Active section platinum ring or gold pin
    Connection Pg 13,5
    temperature range -15 up to +130°C
    Pressure rating up to 6 bar
    salt KCl gel filling
    Diaphragm PTFE (teflon), ring form
  • ORP Electrode with Plastic Sheathing, ARS-X5K
    EXPERT-LINE
    Active section platinum -ring
    Connection NPT 3/4"
    Shock-proof because of plastic case
    temperature range 0 up to 80°C
    Pressure rating up to 7 bar
    Diaphragm PTFE (teflon)
    Cable 5 meters fixed cable
  • Transmitter for Specific Conductivity, ACM-Z
    COMPACT-LINE
    0 up to 200 mS/cm
    With panel mount housing or field mounting housing
    Display of conductivity and temperature with LEDs
    analogue actual-value output scaleable
    2 relays for control functions (PID) programmable
    2 binary inputs
    1 binary output (alarm contact or temperature limit contact)
  • Conductive Conductivity Measuring Cells, ACS-Z
    COMPACT-LINE
    Measuring range 1, K=0,01 0,05 ... 10 µS/cm
    Measuring range 2, K=0,1 0,5 ... 5000 µS/cm
    Measuring range 3, K=1,0 5 µS/cm ... 100 mS/cm
    Connection thread G ¾ A
    Electrode Material st. st. 1.4571 bzw. graphite
    temperature range up to 135°C (at 1 bar)
    Pressure rating up to 16 bar (at 25°C)
    Temperature sensor Pt 100 integrated
  • Transmitter for Specific Conductivity, ACM-X
    EXPERT-LINE
    Measuring range conductivity
    resistance 0 ... 86 M Ohm cm
    With panel mounted housing or field mounted housing
    Large LC-Display for text
    Analogue actual-value output scaleable
    Alarm relays
    Two additional relays for use as control contacts
    Two digital inputs
  • Conductive Conductivity Measuring Cells, ACS-X
    EXPERT-LINE
    Measuring range 1, K=0,01 0,04 ... 20 µS/cm
    Measuring range 2, K=0,1 0,1 ... 200 µS/cm
    Measuring range 3, K=1,0 50 ... 500 µS/cm
    Measuring range 4, K= 1,0 10 µS/cm ... 20 mS/cm
    Connection NPT ½ " or G1"
    Electrode Material st. st. 1.4571 or. graphite
    Temperature sensor Pt 100 possible
  • Inductive Conductivity Measuring Cell ACS-X0I
    EXPERT-LINE
    Measuring range 5 µS/cm up to 2000 mS/cm
    Connection G3/4" of 1.4571 or 1"NPT of PEEK
    Material of sensor PEEK (resistant to chemical attack)
    temperature range -20 up to +130°C
    Pressure rating up to 16 bar
    Cable 5 meters fixed cable
    Temperature sensor coated Pt 100 integrated
  • Accessories for Analysing Devices AZA, AZT, AZM
    Immersion assemblies
    Flow assemblies
    Process assemblies
    Buffer solutions for pH and ORP
    Calibration solutions for conductivity
    temperature sensors
    Wall mounting set for field housing
    Pipe mounting set for field housing
  • Hand-Held pH, Redox, Temperature Measuring Unit HND-R
    Measuring range
    pH 0,00 ...14,00
    Redox -1999 mV...+2000 mV
    Temperature -100,0...+250,0 °C
    Accuracy ± 0,01 pH, ± 0,1 % FS (mV), ± 0,2 (0,4) °C.
    Supply 9 V battery
    hold function, min/max. -memory