Products
-
Digital Panel Indicators DAG
Programmable, 4-digit LED Dimensions 96x48, 96x24, 72x36, 48x24, Input temperature, frequency, current, voltage output 0(4)-20 mA, 0-10 V Options sensor supply, contacts, min/max.-memory
-
Temperature Switch TWR
Switch points +30 ... +120 (in 5 or 10 °C steps) fixed Connection G ¾ male, brass or st. st. Electrical connection plug DIN 43 650 Switching Accuracy 30..+90 °C ± 5 °C 100-120 °C ± 7 °C Hysteris max. 20 °C
-
Thermal Reed Switches TRS
Switch points +10 ... +120 (in 5 bzw. 10 °C Schritten) fixed Connection G ¼...G 1 male, brass or st. st. Electrical connection cable Switching Accuracy ± 3 °C Hysteresis < 7 °C
-
Temperature Switch-Digital TDD-1,-3,-5,-7
Switch points -20 ... +125 °C, adjustable Connection G ½, G¾ male, ½, ¾ NPT st. st. Indication 3-digit LED Electrical connection plug M12x1 or cable Supply 24 VDC Contact 1 or 2 semiconductors PNP/NPN N/O or N/C adjustable Switching Accuracy ±0, 5 °C (-10...+85 °C)
-
Rod and Air-DuctThermostat TEA-L, -S
Switching range -15 ..+30 up to +50... +120, adjustable Connection G ½ or connection plate Material plastic (housing) copper or st. st. (probe) Micro switch SPDT, 24-250 VAC, 15 (8) A single or double contact
-
Room and Surface Thermostat TEA-R,-A
Switching range -30 ..+30 up to +50... +120, adjustable Material plastic (housing) copper or st. st. (probe) Micro switch SPDT, 24-250 VAC, 15 (8) A single or double contact
-
Frost Predection and Capillary Thermostat TEA-F, -K
Switching range -30 ..+30 up to +50... +120, adjustable Connection G ½ or connection plate Material plastic or steel (housing) copper (probe) Micro switch SPDT, 24-250 VAC, 15 (8) A single or double contact
-
Thermostats for industrial Applications TER
Switching range -20 ..+20 up to +80... +130, adjustable Material die-cast metal (housing) copper, brass or st. st. (probe) Micro switch SPDT Max. 250 V 8 (5) A bei 250 VAC 1 A bei 24 VDC
-
Universal Bussystem KOBUS
as plug-on display, 4-digit, red LED up to 240 sensors, BUS-length max. 1km for transmitters with (0)4-20 mA, 0-10 V or 0.5..1000 Hz output and plug DIN 43 650 software for indication, datalogger, configuration
-
Bi-metal Thermometer TBI-I
Measuring range -30 ... +50 up to 0 ... 500 °C Connection back or bottom G ½ AG, st. st. Housing Material st. st. Diameter of housing 63, 80, 100 mm Accuracy class 1,0 Option mark pointer, gliding pointer
-
Digital Thermometer DTM
Measuring range -30 ... +50 up to 0...400 °C Connection back or bottom G ½... G1, 1/2"... 1" NPT Housing Material st. st., back polyamides diameter of housing 100 mm Accuracy class 0,5 Option anlaogue output, up to 2(4) contacts, peak memory, RS 232
-
Infrared Hand-Held Thermometer TIR-HN
Non- contact temperature measurement Measuring range -20 ... +500 up to -32 ... 900 °C Measuring Accuracy ± 1 % up to ±2 % of m. value Option analogue output, RS 232, data memory, Laser pointer, statistical functions
-
Infrared Thermometer (fixed installation) TIR-SA
Measuring range 0 ... 120 up to 100 ... 500 °C Housing Material st. st. Accuracy class ± 1,5 % of m. value (min 2,5 °C) Supply voltage 18-30 VDC output thermic voltage Typ J or K, or 10 mV/°C
-
Glass Thermometer for Machines TGL
Measuring range -60 ... +40 up to 0 ... 200 °C Connection G ½ or ½ NPT, brass Housing Material aluminum Housing length 110, 150 or 200 mm Accuracy class 1,0
-
Shaft Thermometers according to DIN 16205 TNS
Measuring range -20 ... +40 up to 0 ... 600 °C Connection back or bottom G ½... G1, ½ NPT...1" NPT, TriClamp, and so on Housing Material aluminum or st. st. Diameter of housing 63, 80, 100,160 or 250 mm Accuracy class 1,0 or 1,6 Option contacts, gliding pointer, oil filling, and so on
-
Capillary Thermometer Nitrogen Filled TNF
Measuring range -20 ... +40 up to 0... 600 °C Connection back or bottom G ½... G1, ½ NPT...1" NPT, TriClamp, aso. Housing Material aluminum or st. st. Diameter of housing 63, 80, 100,160 or 250 mm Accuracy class 1,0 or 1,6 cCpillary connection up to 100 m Option contacts, Max. pointer, oil filling