Rotating Vane-Pulse-Analogue Output DRH-..F, DRH-..L


Product Specifications
Measuring range 0,2-0,8 L/min ...2,5-50 L/min water
Connection G 3/8, G 1, 3/8 NPT, 1 NPT
Material brass, st. st., POM, PVDF
Max. pressure 100 bar
Max. temperature 100 °C
Accuracy ± 2,5 % FS
Pulse output, analogue output

KOBOLD rotating vane flow meters series DRH are used for measuring and monitoring low viscous liquids. Series DRH flow meters are working according the wellknown rotating vane principle. A magnet fitted in the vane and hermetically sealed from the medium transfers non-contacting the rotary motion to a Hall-effect sensor mounted in the housing. The sensor converts the rotary motion which is proportional to the flow to a frequency signal. A series-connected electronics unit converts the signal to an analogue output, limit contacts or display. This devices can be adapted to prevailing plant conditions with the 360° rotatable screw connections.