Variable Area Flowmeter-Class Cone-Fixed Flange URK


Product Specifications
Measuring range
1-10 L/h ... 15-50 m³/h water
0,02-0,2 ... 20-200 Nm³/h air
Connection flange DN 15...80, ANSI ½"...3"
Material cast iron.
Max. pressure 10 bar
Max. temperature 100 °C
Accuracy ±2,5...4% f.s.