Products

Food

  • All St.St. Bourdon Tube P/G with Diaphragm Seal MAN-R
    Range -1 ... 0 bar up to 0...600 bar
    Connection hygenic connectzion DIN 11851, Triclamp,
    Union nut (IDF-, APV-RJT-, or SMS-Norm), pipe diaphragm seal , diaphragm seal for homogenizing machines.
    Housing material st.st.
    Housing diameter 63, 100, 160 mm
    Accuracy calss 1,6 or 1,0
    Option contacts
  • All Stainless Steel Bourdon Tube Pressure Gauges for Exceptional Safety MAN-R…S
    Measuring range -1 up to 0 ... 0 up to 1000 bar
    Connection G 1/4, G ½ male, st. st.
    Housing Material st. st.
    Diameter of housing 63, 100, 160 mm
    Accuracy class 1,6 or 1,0
    Option contacts, glycerine filling
  • Bypass Level Indicator NBK-03
    Measuring length Max. 6 meters (if longer
    Connection DIN-flange DN 15...DN 32
    ANSI-flange 1/2"... 1 1/4"
    Material st. st. 1.4571
    Max. pressure PN 100, max. temperature
    Accuracy transducer +/- 1 mm
    Option transmitter 4-20 mA, contacts
  • Calorimetric Flow Switch KAL-K4440
    Switching range 4 cm/s ... 2 m/s
    Conn.
    Material st.st.
    Max. pressure 100 bar
    max. temperature 80 °C
    Repeatability approx. 2 %
    LED-chain, relay, analogue output
  • Capacitive Level Limit Switch for bulks NSC
    Electrodes max. 3 m, with cable 15 m
    Contact 1 relay (max. 250 Vac, 1A)
    Connection G 1 male, st. steel
    Material Electrodes st. steel with PTFE or
    steel cable with PP coating
    Max. pressure -0,1 bis +0,5 bar
    Max. temperature -20...+80 °C
    Power supply 24, 110, 230 VAC, 18..36 VDC
  • Capacitive Level Limit Switch LNZ
    As well for non conductive liquids
    sensitive to foam, not for adhesions
    Connection G 1/2
    hygenic mounting system (EHEDG)
    hygenic DIN 11851, Tri-Clamp, weld on sleeve
    Material st.st. 1.4404 / PEEK
    Max. pressure 10 bar
    Max. temperature 100 °C (CIP 150°C)
    Contact Open Collector, PNP, 200 mA
  • Capillary Thermometer Nitrogen Filled TNF
    Measuring range -20 ... +40 up to 0... 600 °C
    Connection back or bottom
    G ½... G1, ½ NPT...1" NPT, TriClamp,
    aso.
    Housing Material aluminum or st. st.
    Diameter of housing 63, 80, 100,160 or 250 mm
    Accuracy class 1,0 or 1,6
    cCpillary connection up to 100 m
    Option contacts, Max. pointer, oil filling
  • Conductive Level Switch Compact , LNK-K
    for conductive liquids (>10 mikroS)
    Electrodes 4 up to 2000 mm
    Connection G ½
    hygenic mounting system (EHEDG)
    hygenic DIN 11851, Tri-Clamp, weld on sleeve
    Material st.st. 1.4404, option
    Max. pressure 10 bar
    Max.temperature150°C
    Option head mounted transmitter f. 1 contact
  • Conductive Level Switch LNK
    For conductive liquids (>10 mikroS)
    Electrodes 1-4 pcs, length
    Connection G 1/2, G 1
    hygenic mounting system (EHEDG)
    hygenic DIN 11851, Tri-Clamp, weld on sleeve
    Material st.st. 1.4404, Option
    Max. pressure 10 bar
    Max.Temperatur100°C (CIP 150 °C)
    Options head mounted transmitter f. 1 contact
  • Contact options for manometers
    for housing dia. 100 mm or 160 mm
    Sliding contacts max. 4 pieces
    max. 250 Vac / 10 W /18 VA / 0,6 A
    Magnetic spring contacts max. 4 pieces
    max. 250 Vac / 30 W /50 VA / 0,6 A
    Inductive contacts acc. to DIN 19234 (NAMUR) max. 2 pieces
    Pneumatic contacts max. 2 pieces
  • Continuous Level Probe LNP
    Potentiometric principle
    For viscous, pasted, strong adhessive medias
    Measuring length 200...2000 mm
    Connection G 1, 1" NPT, G1 for hygenic sleeve LZE
    Material st.st. 1.4404 / PEEK
    Max. pressure 10 bar
    Max. temperature 120°C (short time 150 °C)
    Accuracy ± 1% FS
    Output 4-20 mA
  • Diaphragm, Capsule and Inline Diaphragm Seals for Pressure Gauges DRM
    Diaphragm seals, capsule seals, inline diaphragm seals for pressure gauges
  • Digital Thermometer DTM
    Measuring range -30 ... +50 up to 0...400 °C
    Connection back or bottom
    G ½... G1, 1/2"... 1" NPT
    Housing Material st. st., back polyamides
    diameter of housing 100 mm
    Accuracy class 0,5
    Option anlaogue output, up to 2(4) contacts,
    peak memory, RS 232
  • Electromagnetic Flowmeter DMH
    Measuring range
    Connection flange DN 15...DN300
    Material case lining soft rubber, Ebonite, PTFE, PFA, PA1
    Max. pressure PN 40 bar
    Max.temperature-20...+150°C
    Accuracy± 0,3 % of m. value ±0,01%xQmax.
    Output pulse-/analogue output, status display, totalizer, Hart
  • Electromagnetic-Switch MIK-..S3
    Measuring range 0,01-0,5 ...35-700 L/min liquid
    Connection G ½..G 2 ¾ male
    Material PPS/st. steel PVDF/Hastelloy, Tantalum
    Max. pressure 10 bar
    Max.temperature80°C
    Accuracy± 2 % FS
    Switchpoint
  • Electronic multi-channel datalogger ZLS
    Display Graphic LC-Display, ± 9999
    Dimensions 96x96 mm
    Input 1-, 4-, or 8-channel
    Pt 100, Pt 500, Pt 1000 or 0(4) - 20 mA
    Digital Input 24 VCD (option
    Memory 2 MB
    Interface RS 485, Modbus RTU
    Power Supply 19-50 VDC / 16-35 VAC or 85-260 VAC/VDC
    Sensor Supply 24 VDC
  • Flow, Humidity and Temperature Hand-Held Measuring Unit HND-F115
    For weight moisture or relative humidity
    Measuring range 0(4) -100 % rel. humidity
    Accuracy ± 0,1 / 0,2 % of rel.humidity
    Supply 9 V battery
    Holding Function, min/max. -memory, alarm,
    data logger, output 0-1 V, RS 232
    Option temperature-, flow measuring
  • Hand-Held pH, Redox, Temperature Measuring Unit HND-R
    Measuring range
    pH 0,00 ...14,00
    Redox -1999 mV...+2000 mV
    Temperature -100,0...+250,0 °C
    Accuracy ± 0,01 pH, ± 0,1 % FS (mV), ± 0,2 (0,4) °C.
    Supply 9 V battery
    hold function, min/max. -memory
  • Humidity Annex Switch AFS-G3
    Operating range 50 - 100 % RH
    Max. pressure pressureless
    Max. temperature 0...60 °C
    Accuracy ± 3 %RH
    Contact 1 micro switch, adjustable from inside
  • Humidity/ Temperature Measuring Instrument (capacitive) AFK-G
    Operating range temperature
    humidity 0... 100 % RH
    Max. pressure 25 bar
    Max. temperature +200 °C
    Accuracy of temperature ±0,1 °C
    humidity ± 2 %RH
    Output 2 x 4-20 mA
  • Humidity/temperature Measuring Instrument AFH-G
    Operating temperature -30...+80 °C
    umidity 30..100 % RH
    Probe polymer fibre inside st. st. housing, 220 mm
    Max. pressure pressureless
    Max. temperature -20...60 °C (housing),
    -40..+80 °C (sensor)
    Accuracy of temperature ±0, 5 °C
    humidity ± 2,5 % RH (<40% RH
    Output temperature
    humidity 100-138,5 Ohm or 4-20 mA
  • Hygenic Mounting Systems LZE
    EHEDG-and 3A-certified
    Connection sensor G 1/2, G 3/4, G1, M12x1,5
    Connection prozess weld on sleeve, ball sleeve, collar sleeve, Triclamp, varivent, clamp
    Material st.st. 1.4404
    Max. pressure 10 bar
    Max. temperature 250°C
  • Inductive Conductivity / Concentration and Temperature Transmitter LCI
    Measuring range 0-500 µS/cm...0-2000 mS/cm
    Connection G 1 ¼ AG - 2 AG, screwed pipe conn. DIN 11851, Tri-Clamp®, Varivent®
    Material PEEK. PVDF
    Max.pressure 10 bar
    Max. temperature 120 °C (short term 140 °C)
    Accuracy 1 %
  • Level Modul for Conductive Level Probes, LNR
    for conductive level switches
    output 1 PNP
    power supply15...36 VDC
  • Liquid Level Switch NWS
    For liquids
    Contact 1 Electronic switch
    ConnectionG 3/4, G1 male, ¾ NPT, 1 NPT male,
    TriClamp DIN 32676, hygenic DIN 11851
    DIN-flange DN25, DN50;ANSI-flange
    Material st. st. 1.4404
    Max. pressure45 bar
    Max.temperature130°C (150 °C CIP-cleaning)
    Viscosity up to 5000 mm²/s
  • Microwave Level Switch LNM
    As well for non conductive liquids
    insensitive to foam and adhesions
    Connection G 1/2, M12x1,5;
    hygenic mounting system (EHEDG)
    hygenic DIN 11851, Tri-Clamp, weld on sleeve
    Material st.st. 1.4404 / PEEK
    Max. pressure 10 bar
    Max. temperature 100 °C (CIP 150°C)
    Contact Open Collector, PNP, 50 mA
  • Options for Pressure Gauges
    Our strength manometers in special versions
    Pointer marker ponter, drag pointer, min/max pointer
    Scales special scale, precision scale, customised
    Certificates calibration certificate, DKD certificate,
    cal. insignia, government approved calibration
    Throttle screws brass, stainless steel, 0.5...0.8 mm
    Others oil & fat free, silicon free, spring loaded zero-stop,
    laminated glass, vacuum safe
  • Precision Hand-Held Thermometer HND-T125
    Measuring range -65... +199,9°C, -65..+1150°C
    Probe Thermo couples K
    Accuracy ± 0,05 %, ±0,1 % of m. value
    Supply 9 V battery
    Holding Function, min/max. -memory, °C/°F
  • Predection Pipes for Thermometer TSH
    Connection G ½...G 1, welded 18mm...28 mm
    Material st. st.
    Max. pressure 25 bar
  • Pressure Gauge Digital with Ceramic Sensor Element, Battery Powered MAN-SD
    Measuring range -1 up to 0 ... 0 up to 1600 bar
    Connection G ¼, G ½ male, ¼ NPT, ½ NPT st. st.
    Housing Material glasfibre reinforced plastic
    Diameter of housing 74 mm
    Accuracy class 0,5
    Power supply battery
    Option contact, analogue output, peak memory
  • Pressure Gauges Digital with Ceramic Sensor Element MAN-SF26
    Measuring range -1 up to 0 ... 0 up to 1600 bar
    Connection G ½ AG, st. st.
    Housing Material st. st.
    Diameter of housing 100 mm
    Accuracy class 0,5
    Power supply 18-30 VDC
    Option 2/4 contacts, analogue output, RS 232, peak memory, controlling of compressors, differential pressure
  • Pressure Sensor Ceramic Element and Diaphr. Seal SEN
    For relative pressure
    Range -1...0 bar up to 0 ...600 bar
    Connection hygenic connection DIN 11851, Triclamp,
    Union nut (IDF-, APV-RJT-, or SMS-Norm), pipe diaphragm seal, diaphragm seal for homogenizing machines
    Accuracy class 0,5 or 1,0
    Analogue output
  • Pressure Sensors with Ceramic Element PDA
    Measuring range -1 up to 0 bar ... 0 up to 400 bar
    Connection G 1/4, G 1/2, ¼ NPT, ½ NPT
    Housing st. st.
    Max. temperature80 °C (media)
    analogue output 0(4)-20 mA, programmable,
    Semiconductor PNP/NPN, digital display
  • Pressure Switch with Ceramic Element PDD
    Switching range -1 up to 0 bar ... 0 up to 400 bar
    Connection G 1/4, G 1/2, ¼ NPT, ½ NPT
    Housing st. st.
    Max. temperature80 °C (media)
    1 or 2 Semiconductor PNP/NPN,
    digital display, programmable
  • Resistance Temperature Probe with Connection Box LTS-A
    Pt100, class A acc. DIN IEC 751
    Range -50...+250 °C
    Connection G 1/2, M12 for hygenic sleeve LZE
    Material st.st.
    Max. pressure 10 bar
    Option head mounted transmitter 4-20 mA, fast responding sensor tip, longer neck for higher temperatures
  • Rotating Vane Level Monitor NIR
    For bulks
    Contact 1 micro switch
    Connection G 1, G 1 ½ male, roand flange
    Material shaft/Rotor
    Max. pressure 0,5 bar
    Max .temperature 80 °C
  • Rotating Vane-Low Volume-Pulse Output DPL-..F5
    Measuring range 0,025-0,5 L/min ...1-25 L/min water
    Connection G ½ male or hose connector
    Material Polypropylene
    Max. pressure 10 bar
    Max. temperature 70 °C
    Linearity ± 1%
    Pulse output, frequency divider
  • Shaft Thermometers according to DIN 16205 TNS
    Measuring range -20 ... +40 up to 0 ... 600 °C
    Connection back or bottom
    G ½... G1, ½ NPT...1" NPT, TriClamp, and so on
    Housing Material aluminum or st. st.
    Diameter of housing 63, 80, 100,160 or 250 mm
    Accuracy class 1,0 or 1,6
    Option contacts, gliding pointer, oil filling, and so on
  • Turbidity Meter ATL
    Measuring range 0...3 CU
    Connections DIN-/ ANSI-flange, NPT, BSP thread, hygenic connection
    Material st. st.
    Max. pressure 10 bar
    Max. temperature 0...100°C
    Output 4...20 mA, 2 limit switches
  • Variable Area Flowmeter-All Metal BGN
    Measuring -/switching range
    0,5 - 5 ..13.000 -130.000 L/h water
    0,015 - 0,15 ...240 -2.400 Nm³ /h air
    Connection flange DN 15 ... DN 150, ANSI 3/4"... 6"
    Material st. st. 1.4404, PTFE-lining, Hastelloy
    Max. pressure PN 40 (16) bar
    Max. temperature 350°C
    Accuracy ±1,6% of m. value (±2% of m. value for gases)
    Options contacts, analogue output, totalizer,
    Hart, Profibus PA, ATEX
  • Variable Area Flowmeter-Plastic KSM
    Meas. -/switching range 15-150...8000-60000 L/h water
    0,8-5...100-860 m³/h air ( 0 bar rel., 20°C)
    Connection G 1 ½..G 3 1/2; glue-in - DN 25...DN 65
    Material trogamide-T, polysulfone
    Max. pressure PN 16
    Max. temperature 60 °C (trogamide), 100 °C
    (polysulfone), 140 °C (PVDF)
    Accuracy class 4
    Option reed contact
  • Vibrating Level Switch SOLIVIB NSV
    For powder, granulate
    Electrodes max. 3 m
    Contact 1 relay (max. 250 VAC, 1A), 25 VA
    Connection G 1 ½ male
    Material st. st. 1.4305 (303)
    Max. pressure pressureless
    Max.temperature 80 °C
    Power supply 24, 110, 230 VAC, 18...36 VDC
    Certificates ATEX

Accessories

  • Absolute Rotation Transmitter, Multiturn ZDA-M
    Shaft or hollow shaft
    Max. No. of revolutions 6000 min-1
    shaft up to D=28 mm
    8192 positions per revolution and 4096 revolutions
    Code Gray
    Interface RS485, SSI, programmable
    12-pin plug connector
    Supply 5-30 VDC
    Max. temperature +70 °
  • Absolute Rotation Transmitter, Singleturn ZDA-SH
    Hollow shaft style
    Max. No. of revolutions 6000 min-1
    Holllow shaft D= 10/12 mm
    Max. resoution 14 bit
    Code Gray/Gray-Excess
    Interface parallel
    17-pin plug connector
    Supply 10-30 VDC
    Max. temperature +85 °
  • Absolute Rotation Transmitter, Singleturn ZDA-SW
    Shaft style
    Max. No. of revolutions 12 000 min-1
    Shaft D=6/10 mm
    Max. resoution 13 bit
    Code Gray/Gray-Excess
    Interface parallel
    17-pin plug connector
    Supply 10-30 VDC
    Max. temperature +85 °
  • Accessories Rotation Transmitter ZDZ
    12- and 17-pin plug
    Shaft style metal bellow coupler, angle flange
    Rectangular flange, mounting eccenter for synchro- flange
    Hollow shaft style stator coupling, mounting set
  • Air Eliminator ZAL
    Filter grade 40...200 µm
    Connection Flansch ANSI 1"...4"
    Max. pressure 10 bar
    Max. temperature 70 °C
  • Ball Valve with integr. Sensor Connection KUG-S
    Change of sensor without evacuating the pipe
    Connection Rp ½...Rp 2, sensor G ¼..G 1/2
    Material brass nickle plated
    Max. pressure PN 25
    Max. temperature 120°C
  • Ball Valve with Pneum. Actuator KUP-VO
    2-way version
    Connection flange DN 25..DN 200
    Material brass, GG
    Max. pressure PN 16
    Max. temperature 160 °C
  • Ball Valves with Flange Connection KUG-VO
    2-way
    Connection flange DN 25...DN 200
    Materialgrey cast iron
    Max. pressure PN 16 (80°C)
    Max. temperature 120°C
  • Batching electronic ZED-D
    Display 2x LC-Display, alphanumeric,
    8-digit (quantity), 5-digit (batching quantity)
    Dimensions 96x96 or 116x116 (field housing)
    Input 0,2...2000 Hz (5-24 VDC)
    Control Input Start, stop and reset function
    Output 0(4) - 20 mA, 2x change-over contacts
    Power Supply 24 VDC or 90-250 VAC
    Sensor Supply 12V/ 15 V
    Menu guided, password, teach-in operation
  • Brass Ball Valve KUG-TB,-VN,-VC
    2-and 3-way with thread
    Connection G ¼...G3
    Material brass nickle plated
    Max. pressure PN 50
    Max. temperature 150°C / 220°C
    Option DIN-DVGW-registration
  • Compact Chart Recorder KLS
    Input standard current-and voltage signals
    resistance thermometers, thermocouples
    4 control inputs
    Output 4 relays, RS 485
    Power supply 290...253 VAC, 18...30 VAC/DC
    Option date, time- and text block
  • Counter and Dosing Electronic ZOD
    Display 2x LC-Display, alphanumeric,
    Power Supply 24 VDC or battery
  • Counter electronic ZED-Z
    Display 2x LC-Display, alphanumeric,
    8-digit (quantity), 3 or 4 digit (flow)
    Dimensions 96x96 or 116x116 (field housing)
    Input 0,2...2000 Hz (5-24 VDC)
    Control Input reset function
    Output 0(4) - 20 mA, 2x change-over contacts
    Power Supply 24 VDC or 90-250 VAC
    Sensor Supply 12V/ 15 V
    Menu guided, password, teach-in operation
  • Digital Panel Indicators DAG
    Programmable, 4-digit LED
    Dimensions 96x48, 96x24, 72x36, 48x24,
    Input temperature, frequency, current, voltage
    output 0(4)-20 mA, 0-10 V
    Options sensor supply, contacts, min/max.-memory
  • Electrical Connecting Accessories ZUB-KAB
    Circular connector M12
  • Electronic multi-channel datalogger ZLS
    Display Graphic LC-Display, ± 9999
    Dimensions 96x96 mm
    Input 1-, 4-, or 8-channel
    Pt 100, Pt 500, Pt 1000 or 0(4) - 20 mA
    Digital Input 24 VCD (option
    Memory 2 MB
    Interface RS 485, Modbus RTU
    Power Supply 19-50 VDC / 16-35 VAC or 85-260 VAC/VDC
    Sensor Supply 24 VDC
  • Electronic Service Hour Meter ZEC-1
    Input Pulse totalizer, frequency counter, Time counter, Position indication
    Indicator 6-digit LED
    Digit size 8 mm
    Operation via front buttons
    Material plastics
    DIN-housing 48x24 mm,panel mount housing
    Power supply 24 VDC
  • Electronic Service Hour Meter ZEC-1Z
    Input time totaliser
    Indication 6 digit, LED
    Dimensions 48x24
    Output opto-coupler
    Programming via front buttons
    Material plastic
    Panel mounting
    Power supply 10-30 VDC
  • Electronic Service Hour Meter ZEC-4K
    Combined instrument
    Input pulse totalizer, time counter
    Indication 6-digit LED
    Digit size 14 mm
    Operation via front buttons
    Material plastic
    DIN-housing 96x48 mm, panel mount housing
    Supply 10-30 VDC / 90-260 VAC
  • Electronic Service Hour Meter ZEC-4M
    Multi function instrument
    Input Pulse totalizer, frequency counter, time counter
    Indicator 6-digit LED
    Digit size 14 mm
    Output opto-coupler
    Operation via front buttons
    Material plastic
    DIN-housing 96x48 mm, panel mount housing
    Supply 10-30 VDC / 90-260 VAC
  • Electronic Service Hour Meter ZEC-4Z
    Input time totaliser
    Indicator 6-digite LED
    Digit size 14 mm
    Operation via front buttons
    Material plastics
    DIN-housing 96x48 mm, panel mounting housing
    Power supply 10-30 VDC / 90-260 VAC
  • EX-Absolute Rotation Transmitter, Singleturn ZDA-E
    Shaft or hollow shaft
    Max. No. of revolutions 6000 min-1
    Shaft/hollow shaft D=12 mm
    Max. graduation 14 bit, code
    Interface parallel
    Electrical connection 2 m cable
    Supply 10-30 VDC
    EEx d IIC T6
    Max. temperature +60 °
  • EX-Incremental Rotation Transmitter ZDI-E
    Shaft or hollow shaft
    Max. No. of revolutions 6000 min-1
    Shaft/hollow shaft D=12 mm
    Output RS422 or push pull
    Electrical connection 2 m cable
    Pulse rate Max. 5000 pulses
    Max. pulse frequency 300 kHz
    Supply 10-30 VDC, EEx d IIC T6
    Max. temperature +60 °
  • Flow Regulators REG
    Flow 1,2,3,4,6,8,9,10,11,12,16,20,25,30,40 L/min water
    Connection G 1/2, G 3/4, ¾ NPT
    Material brass, st. st.
    Max. pressure 10 bar
    Max. temperature 300 °C
  • Frequency Transmiter FMU
    Dimensions 75x45x110 mm
    Inputfrequency up to 40 kHz, NPN, PNP, Namur
    Output 0(4)-20 mA, 0-10 V
    Power supply 115, 230 VAC, 24 VDC
  • Incremental Rotation Transmitter ZDI-BH
    Hollow shaft style
    Max. No. of revolutions 6000 min-1
    Shaft D=10/12 mm
    Output RS422 or push pull
    Electrical connection 1 m cable
    Pulse rate 10-5000 pulses
    Max. pulse frequency 300 kHz
    Supply 5 VDC, 10-30 VDC
    Max. temperature +75 °C
  • Incremental Rotation Transmitter ZDI-BW
    Shaft style
    Max. No. of revolutions 12 000 min-1
    Shaft D=6/10 mm
    Output RS422 or push pull
    12-pin plug connector
    Pulse rate 10-5000 pulses
    Max. pulse frequency 300 kHz
    Supply 5 VDC, 10-30 VDC
    Max. temperature +75 °C
  • Incremental Rotation Transmitter ZDI-CH
    Large hollow shaft
    Max. No. of revolutions 1500 min-1
    Shaft up to D= 42 mm
    Output RS422 or push pull
    12-wire plug connector
    Pulse rate 360-5000 pulses
    Max. pulse frequency 300 kHz
    Supply 5 VDC, 10-30 VDC
    Max. temperature +75 °
  • Industrial Batcher, Counter, Flowindicator DAG-AXI
    Programmable, 6-digit LED
    1 totalizer/diference/distant indication,1 rate meter min/Max.-memory
    Dimensions 96x48
    Inputfrequency up to 34 kHz
    Output 0(4)-20 mA, 0-10 V, 4 contacts, RS232/485
  • Isolation Switching Amplifier for Initators KFD-2, KFA-6
    Single channel,
    Protection EEx ia IIC
    Input intrinsicly safe acc. NAMUR or. DIN 19234
    output SPDT, non instrinsicly safe
    Power supply 230 VAC or 24 VDC
    Mounting rail mounting
  • Isolation Switching Amplifier for Pulse Generators REL-7
    For transmission of pulse signals
    Protection EEx ia IIC
    Input intrinsicly safe, up to 5 kHz
    output non intrinsicly safe,
    1-Signal
    Electronic output active
    2-line interruption,
    Electronic output active
    Power supply 20..30 VDC
    Mounting rail mounting
  • Magnet Filter MFR
    Connection Rp 1/2 ... Rp 3
    Material red cast
    Max. pressure PN 16
    Max. temperature 200 °C
    Filter 280 / 530 µm
  • Miniature-Incremental-Rotation Transmitter ZDI-AH
    Hollow shaft style
    Max. No. of revolutions 12 000 min-1
    Holllow shaft D=4/6 mm
    output push pull
    Electrical connection 2 m cable
    Pulse rate 50-1024
    Max. pulse frequency. 160 kHz
    Supply 5-24 VDC
    Max. temperature +85 °C
  • Miniature-Incremental-Rotation Transmitter ZDI-AW
    Shaft style
    Max. No. of revolutions 12 000 min-1
    ShaftD=4/6 mm
    Output push pull
    Electrical connection 2 m cable
    Pulse rate 50-1024
    Max. Impulsfreq. 160 kHz
    Supply 5-24 VDC
    Max. temperature +85 °
  • Non-Return Valve KUR
    Connection G ¼...G4
    Material brass, st. st.
    Max. pressure PN 25
    Max. temperature 110 °C
  • Power Supply Unit for 2-Wire Transmitters REL-4
    Single channel,
    Protection EEx ia IIC
    input intrinsicly safe, 4-20 mA
    output nicht intrinsicly safe, 4-20 mA,
    available voltage 20 VDC
    Power supply 24 VDC
    Mounting rail mounting
  • Pulse-Contact Predection Relay MSR
    Pulse controlled, for increase of switching capacity
    output max. potential free change-over or
    1 potential free change-over up totable
    Power supply 230 VAC
    Mounting rail mounting
  • Robust Counter for Bracket Mounting ZMZ-2R
    Input pulse totaliser
    Indication 6- and 8-digit
    Housing plastic
    Panel mounting
    Power supply
    24 VDC; 230 VAC
  • Service Hour Meter f. DIN-rail mounting ZBS-9S
    Input service hour meter
    Indicator 6-digit, hours white, decimal figure schwarz
    Digit size 3,5 x1,5 mm
    Material plastics
    Housing 36x90x60 mm ,for DIN-rails
    Power supply 10-27 VDC , 230 VAC
  • Service Hour Meter ZBS-2S
    Input Service hour meter
    Indicator 7/8-digit, hours white, decimal figure red
    Digit size ca. 4 mm optical
    Material plastics
    Housing 36x24, 35,5x26 mm, panel mount
    Power supply 10-30 VDC, 100-130 VAC (60Hz), 187-264 VAC (50Hz)
  • Shut-Off Valves KLA
    Connection wafer DN 40...DN 300
    Material aluminum, GGG
    Max. pressure PN 16
    Max. temperature 180 °C
  • Shut-Off Valves with Electrical Actuator KLE
    Connection flange DN 40... DN 80
    Material aluminum, GGG
    Max. pressure PN 16
    Max. temperature 160 °C
    Power supply, 24 VDC, 230 VAC
    additional limit switch, optical position indicator, emergency
    manual operation
  • Shut-Off Valves with pneum. actuator KLP
    Connection flange DN 40... DN 350
    Material aluminum, GGG
    Max. pressure PN16
    Max. temperature 160 °C
  • Special Incremental-Rotation Transmitter ZDI-DH
    Stainless steel hollow shaft
    Max. No. of revolutions 6000 min-1
    Holllow shaft D=10 mm and 12 mm
    Output RS422 or push pull
    Electrical connection 1 m cable
    Pulse rate Max. 5000 pulses
    Max. pulse frequency 300 kHz
    Supply 5 VDC, 10-30 VDC
    Max. temperature +85 °
  • St. St. Ball Valves KUG-ZE,-KD
    2-and 3-way with thread or welding ends
    Connection G ¼...G 2, welding ends DN10..DN50
    Material st. st.
    Max. pressure PN 64
    Max. temperature 180°C
  • St.St.-Ball Valve with Electric Actuator KUE-VH, -ZA, -PD
    2-and 3-way version
    Connection G ½..G 2
    Material steel, st. st.
    Max. pressure PN 16
    Max. temperature 120 °C
    Power supply 24 VDC, 230 VAC
    additional limit switch, optical position indicator, emergency
    manual operation
  • Standard Service Hour Meter ZBS-4S
    Input service hour meter
    Indicator 7-/8-digit, hours white, decimal figure red
    Digit size 4 mm
    Material plastics
    Housing 48x48 mm ,panel mount
    Power supply 10-30 VDC, 100-130 VAC (60Hz), 187-264 VAC (50Hz)
  • Time and Pulse Totalizer Combination ZBS-4K
    Input pulse and service hour meter
    Indicator 2x 7-/8-digit, hours white, decimal figure red
    Digit size 4x1,7 mm optical
    Material plastics
    Housing 48x48 mm ,panel mount
    Power supply 10-30 VDC, 100-130 VAC (60Hz), 187-264 VAC (50Hz)
  • Universal Batch Controller ADI-Z
    8-digit LCD for totalizer
    4,5 (4)-digit LCD for flow,pressure, temperature
    Dimensions 96x96x105 mm, 116x116x123 mm
    Inputfrequency 0,5-2000 Hz, 4-20 mA (pressure), Pt100/3-L. (temp.)
    Steuereingänge Fernstart/-stop, TTL-Pegel
    Output 0(4)-20 mA, 0-10 V, 2 relays or 2 open collector
    1x Sensor supply5 /12 /24 VDC
  • Universal Bussystem KOBUS
    as plug-on display, 4-digit, red LED
    up to 240 sensors, BUS-length max. 1km
    for transmitters with (0)4-20 mA, 0-10 V or
    0.5..1000 Hz output and plug DIN 43 650
    software for indication, datalogger, configuration
  • Universal Indicator ADI-B..X
    Indicator bargraph
    Input current, voltage, frequency
    Housing 96x96 mm
    Option analogue -, frequency output, contacts,
    Sensor supply
    Mounting panel mounting
  • Universal Indicators ADI-B…F
    Indicator bargraph
    Input current ,voltage, frequency
    Housing 116x116x123 mm
    Option analogue-, frequency output, contacts, sensor supply
    Mounting wall- or pipe mounting
  • Valves NAD-M,-Z
    Control valves
    Connection G 1/8...G 1 1/4, 1/8 NPT...1 NPT
    Material st. st.
    Max. pressure PN 250
    Max. temperature 120 °C

Analysis

  • Accessories for Analysing Devices AZA, AZT, AZM
    Immersion assemblies
    Flow assemblies
    Process assemblies
    Buffer solutions for pH and ORP
    Calibration solutions for conductivity
    temperature sensors
    Wall mounting set for field housing
    Pipe mounting set for field housing
  • Conductive Conductivity Measuring Cells, ACS-X
    EXPERT-LINE
    Measuring range 1, K=0,01 0,04 ... 20 µS/cm
    Measuring range 2, K=0,1 0,1 ... 200 µS/cm
    Measuring range 3, K=1,0 50 ... 500 µS/cm
    Measuring range 4, K= 1,0 10 µS/cm ... 20 mS/cm
    Connection NPT ½ " or G1"
    Electrode Material st. st. 1.4571 or. graphite
    Temperature sensor Pt 100 possible
  • Conductive Conductivity Measuring Cells, ACS-Z
    COMPACT-LINE
    Measuring range 1, K=0,01 0,05 ... 10 µS/cm
    Measuring range 2, K=0,1 0,5 ... 5000 µS/cm
    Measuring range 3, K=1,0 5 µS/cm ... 100 mS/cm
    Connection thread G ¾ A
    Electrode Material st. st. 1.4571 bzw. graphite
    temperature range up to 135°C (at 1 bar)
    Pressure rating up to 16 bar (at 25°C)
    Temperature sensor Pt 100 integrated
  • Flow, Humidity and Temperature Hand-Held Measuring Unit HND-F115
    For weight moisture or relative humidity
    Measuring range 0(4) -100 % rel. humidity
    Accuracy ± 0,1 / 0,2 % of rel.humidity
    Supply 9 V battery
    Holding Function, min/max. -memory, alarm,
    data logger, output 0-1 V, RS 232
    Option temperature-, flow measuring
  • Gel Filled Combined Electrode, ARS-X1Q
    EXPERT-LINE
    Active section platinum ring or gold pin
    Connection Pg 13,5
    temperature range -15 up to +130°C
    Pressure rating up to 6 bar
    salt KCl gel filling
    Diaphragm PTFE (teflon), ring form
  • Gel Filled ORP Electrode, ARS-Z
    COMPACT-LINE
    Sctive section platinum or gold
    Connection Pg 13,5
    temperature range -10°C up to +90°C
    Pressure rating up to 10 bar
    Salt KCl gel filling
    Diaphragm ceramic or (PTFE)- ring
    Salt bridge for longer life time
  • Gel-filled pH-Combined Electrode APS-X1Q
    EXPERT-LINE
    Measuring range pH 0 up to 12
    Connection Pg 13,5
    temperature range -5°C up to +80°C
    Pressure rating up to 10 bar
    Salt KCl gel filling
    Diaphragm ceramic or (PTFE)- ring
    Temperature sensor Pt 100 possible
  • Gel-filled pH-Combined Electrode APS-Z
    COMPACT-LINE
    Measuring range pH 0 up to 12
    Connection Pg 13,5
    temperature range -5°C up to +80°C
    Pressure rating up to 10 bar
    Salt KCl gel filling
    Diaphragm ceramic or (PTFE)- ring
    Temperature sensor Pt 100 possible
  • Hand-Held Conductivity Measuring Unit HND-C
    Measuring range
    conductivity 0,0...200.0 mikroS up to 0,0...200.0 mS
    temperature -5,0...+100,0 °C
    Accuracy
    conductivity ± 0,5v. MV, /± 0,3 % v. FS
    temperature ± 0,2 % v. MV ± 0,3 K
    Supply 9 V battery
    Hold function, min/max. -memory
    Output RS 232 or USB
  • Hand-Held pH, Redox, Temperature Measuring Unit HND-R
    Measuring range
    pH 0,00 ...14,00
    Redox -1999 mV...+2000 mV
    Temperature -100,0...+250,0 °C
    Accuracy ± 0,01 pH, ± 0,1 % FS (mV), ± 0,2 (0,4) °C.
    Supply 9 V battery
    hold function, min/max. -memory
  • Humidity Annex Switch AFS-G3
    Operating range 50 - 100 % RH
    Max. pressure pressureless
    Max. temperature 0...60 °C
    Accuracy ± 3 %RH
    Contact 1 micro switch, adjustable from inside
  • Humidity Measuring Instrument with Indicator (capacitive) AFA-G
    Operating range 0 - 100 % RH
    Max. pressure pressureless
    Max. temperature 0...60 °C
    Accuracy ± 2 % RH (5...95 % RH)
    output 4-20 mA
    Plug-on display 3,5-digit LED
    Option limit switch
  • Humidity/ Temperature Measuring Instrument (capacitive) AFK-G
    Operating range temperature
    humidity 0... 100 % RH
    Max. pressure 25 bar
    Max. temperature +200 °C
    Accuracy of temperature ±0,1 °C
    humidity ± 2 %RH
    Output 2 x 4-20 mA
  • Humidity/temperature Measuring Instrument AFH-G
    Operating temperature -30...+80 °C
    umidity 30..100 % RH
    Probe polymer fibre inside st. st. housing, 220 mm
    Max. pressure pressureless
    Max. temperature -20...60 °C (housing),
    -40..+80 °C (sensor)
    Accuracy of temperature ±0, 5 °C
    humidity ± 2,5 % RH (<40% RH
    Output temperature
    humidity 100-138,5 Ohm or 4-20 mA
  • Hygrostat AFS-G1
    Operating range 35 - 100 % RH
    Probe polymere fibres inside st. st. housing, 220 mm
    Max. pressure pressureless
    Max. temperature -30...60 °C
    Accuracy ± 3,5 % RH (<50%RH
    Contact 1 micro switch
  • Inductive Conductivity / Concentration and Temperature Transmitter LCI
    Measuring range 0-500 µS/cm...0-2000 mS/cm
    Connection G 1 ¼ AG - 2 AG, screwed pipe conn. DIN 11851, Tri-Clamp®, Varivent®
    Material PEEK. PVDF
    Max.pressure 10 bar
    Max. temperature 120 °C (short term 140 °C)
    Accuracy 1 %
  • Inductive Conductivity Measuring Cell ACS-X0I
    EXPERT-LINE
    Measuring range 5 µS/cm up to 2000 mS/cm
    Connection G3/4" of 1.4571 or 1"NPT of PEEK
    Material of sensor PEEK (resistant to chemical attack)
    temperature range -20 up to +130°C
    Pressure rating up to 16 bar
    Cable 5 meters fixed cable
    Temperature sensor coated Pt 100 integrated
  • ORP Electrode with Plastic Sheathing, ARS-X5K
    EXPERT-LINE
    Active section platinum -ring
    Connection NPT 3/4"
    Shock-proof because of plastic case
    temperature range 0 up to 80°C
    Pressure rating up to 7 bar
    Diaphragm PTFE (teflon)
    Cable 5 meters fixed cable
  • pH Electrode with Plastic Sheathing, APS-X5K
    EXPERT-LINE
    Measuring range pH 0 up to 11
    Connection NPT 3/4"
    Shock-proof because of plastic case
    Temperature range 0 up to 80°C
    Pressure rating up to 7 bar
    Diaphragm PTFE (teflon)
    Temperature sensor Pt 100 possible
    Cable 5 m fixed cable
  • Room Hygrostat AFS-G2
    Operating range 35 - 100 % RH
    Max. pressure pressureless
    Max. temperature 0...60 °C
    Accuracy ± 3 % RH
    Contact 1 micro switch, adjustable
  • Transmitter for ORP, ARM-Z
    COMPACT-LINE
    Measuring range -1999 up to +1999 mV
    Withpanel mounted housing or field mounted housing
    Display of ORP and temperature with LEDs
    analogue actual-value output scaleable
    2 relays for control functions (PID) programmable
    2 binary inputs
    1 binary output (alarm contact or temperature limit contact)
  • Transmitter for Specific Conductivity, ACM-Z
    COMPACT-LINE
    0 up to 200 mS/cm
    With panel mount housing or field mounting housing
    Display of conductivity and temperature with LEDs
    analogue actual-value output scaleable
    2 relays for control functions (PID) programmable
    2 binary inputs
    1 binary output (alarm contact or temperature limit contact)
  • Transmitter for Specific Conductivity, ACM-X
    EXPERT-LINE
    Measuring range conductivity
    resistance 0 ... 86 M Ohm cm
    With panel mounted housing or field mounted housing
    Large LC-Display for text
    Analogue actual-value output scaleable
    Alarm relays
    Two additional relays for use as control contacts
    Two digital inputs
  • Transmitters for pH-Value and ORP, APM-X
    EXPERT-LINE
    Measuring range pH
    Redox -1500 up to +1500
    With panel mounted housing or field mounted housing
    Large text LC-Display
    analogue actual-value output scaleable
    Alarm relays
    Two additional relays for use as control contacts
    two digital inputs
  • Transmitters for pH-value APM-Z
    COMPACT-LINE
    Measuring range pH -1 up to 14
    With panel mounted housing or field mounted housing
    Display of pH-value and temperature with LEDs
    analogue actual-value output scaleable
    2 relays for control functions (PID) programmable
    2 binary inputs
    1 binary output (alarm contact or temperature limit contact)
  • Turbidity Meter ATA-K
    Absorbtion method (infrared)
    Measuring range 0...4 CU
    Connections DIN-/ ANSI-flange, NPT, BSP-thread, hygenic connection
    Material st. st.
    Max. pressure 16 bar
    Max. temperature 0...10°C (short-time 120°C)
    Measuring Accuracy +/-2% FS
    Output 4...20 mA, 2 limit switches
  • Turbidity Meter ATL
    Measuring range 0...3 CU
    Connections DIN-/ ANSI-flange, NPT, BSP thread, hygenic connection
    Material st. st.
    Max. pressure 10 bar
    Max. temperature 0...100°C
    Output 4...20 mA, 2 limit switches
  • Turbidity Meter ATS-K
    Dual Light Scattering-method (11°)
    Measuring range 0...500 ppm
    Connections DIN-/ ANSI-flange, NPT, BSP thread, hygenic connection
    Material st. st.
    Max. pressure 16 bar
    Max. temperature 0...190°C
    Measuring Accuracy +/- 2% FS
    Output 4...20 mA, 2 limit switches
  • Universal Bussystem KOBUS
    as plug-on display, 4-digit, red LED
    up to 240 sensors, BUS-length max. 1km
    for transmitters with (0)4-20 mA, 0-10 V or
    0.5..1000 Hz output and plug DIN 43 650
    software for indication, datalogger, configuration

Level

  • Bypass Level Indicator Low Cost NBK-01
    Measuring length Max. 6 meters
    Connection G ½, G 3/4, G1, G11/4
    1/2, 3/4, 1, 1 ¼ NPT
    Material st. st. 1.4301
    Max. pressure PN 16, Max. temperature
    Accuracy transducer +/- 1 mm
    Option transmitter 4-20 mA, contacts
  • Bypass Level Indicator MBSK
    Measuring length Max. 6 meters (if longer
    Connection DIN-flange DN 15...DN 32
    ANSI-flange 1/2"... 1 1/4"
    Material st. st. 1.4571
    Max. pressure PN 100, max. temperature
    Accuracy transducer +/- 1 mm
    Option transmitter 4-20 mA, contacts
  • Bypass Level Indicator NBK with ATEX and GL
    Measuring length Max. 6 meters (if longer
    Connection DIN-flange DN 15...DN 32
    ANSI-flange 1/2"... 1 1/4"
    Material st. st. 1.4571
    Max. pressure PN 100, max. temperature
    Accuracy transducer +/- 1 mm
    Option transmitter 4-20 mA, contacts
    Certificates ATEX, GL
  • Bypass Level Indicator NBK-03
    Measuring length Max. 6 meters (if longer
    Connection DIN-flange DN 15...DN 32
    ANSI-flange 1/2"... 1 1/4"
    Material st. st. 1.4571
    Max. pressure PN 100, max. temperature
    Accuracy transducer +/- 1 mm
    Option transmitter 4-20 mA, contacts
  • Bypass Level Indicator rope version NBK-19
    for open vessels
    Measuring length Max. 4,8 meters
    Float PPH or st. steel
    Max. pressure pressureless, max. temperature
    Accuracy transducer +/- 1 mm
    Option transmitter 4-20 mA, contacts, scale
  • Bypass Level Indicator SZM
    Measuring length 370...3080 mm
    Connection DIN-flange DN 15...DN 32
    Material st. st. 1.4571
    Max. pressure 6 bar
    Max. temperature 100 °C
  • Bypass Level Switch NBA, NBE
    For liquids
    Contact 1 reed switches
    ConnectionG 3/8, R ½
    Materialaluminum, st. st.
    Max. pressure 10 bar
    Max.temperature 90 °C
    Liquid density from 0,65 g/ml on
  • Capacitive Level Limit Switch for bulks NSC
    Electrodes max. 3 m, with cable 15 m
    Contact 1 relay (max. 250 Vac, 1A)
    Connection G 1 male, st. steel
    Material Electrodes st. steel with PTFE or
    steel cable with PP coating
    Max. pressure -0,1 bis +0,5 bar
    Max. temperature -20...+80 °C
    Power supply 24, 110, 230 VAC, 18..36 VDC
  • Capacitive Level Limit Switch LNZ
    As well for non conductive liquids
    sensitive to foam, not for adhesions
    Connection G 1/2
    hygenic mounting system (EHEDG)
    hygenic DIN 11851, Tri-Clamp, weld on sleeve
    Material st.st. 1.4404 / PEEK
    Max. pressure 10 bar
    Max. temperature 100 °C (CIP 150°C)
    Contact Open Collector, PNP, 200 mA
  • Capacitive Level Limit Switch NCW
    For liquids
    Electrodes max. 4 m
    Contact 1 relay (max. 250 Vac, 1A)
    Connection G 1 male, st. steel or G 2 male, PVDF
    Material Electrodes st. steel with PTFE or PVDF coating
    Max. pressure PN 10 bar
    Max. temperature 90 °C (125 °C)
    Power supply 24, 110, 230 VAC, 18..36 VDC
  • Capacitive Level Limit Switch NTS
    For powder, granulate
    Contact 1 open collector or relay
    Connection R1 (G 1 1/2) male
    Material probe PPS
    Max. pressure 25 bar
    Max. temperature 120°C
  • Capacitive Level Meter NMC
    For liquids
    Measuring length max. 4 m
    Connection G 1 male, st. steel or G 2 male, PVDF
    Material st. steel with PTFE or PVDF coating
    Max. pressure PN 10 bar
    Max. temperature 90 °C (125 °C)
    Power supply 12...35 VDC (Atex 12..30 VDC)
    analogue output 4-20 mA
  • Conductive Level Switch (WHG) NEW
    For conductive liquids
    Contact 2 contacts via relays
    ConnectionG 1, G 11/2 male, 1 NPT, 11/2 NPT male
    Material st. st., hastelloy, titanium
    Max. pressure pressureless
    Max.temperature60°C
    For conductive liquids (>20 mikroS/cm)
  • Conductive Level Switch Compact , LNK-K
    for conductive liquids (>10 mikroS)
    Electrodes 4 up to 2000 mm
    Connection G ½
    hygenic mounting system (EHEDG)
    hygenic DIN 11851, Tri-Clamp, weld on sleeve
    Material st.st. 1.4404, option
    Max. pressure 10 bar
    Max.temperature150°C
    Option head mounted transmitter f. 1 contact
  • Conductive Level Switch LNK
    For conductive liquids (>10 mikroS)
    Electrodes 1-4 pcs, length
    Connection G 1/2, G 1
    hygenic mounting system (EHEDG)
    hygenic DIN 11851, Tri-Clamp, weld on sleeve
    Material st.st. 1.4404, Option
    Max. pressure 10 bar
    Max.Temperatur100°C (CIP 150 °C)
    Options head mounted transmitter f. 1 contact
  • Conductive Level Switch NEK
    For conductive liquids
    Contact 1 open collector or 1 relay
    ConnectionG ¾ male, ¾ NPT
    Material PPS, Polypropylen
    Max. pressure 20 bar
    Max.temperature85°C
    For conductive liquids (>28 mikroS/cm)
  • Conductive Level Switch NES
    For conductive liquids
    Contacts 5 contacts via relays
    ConnectionG 1/2, G 11/2 male, ½ NPT, 11/2 NPT male
    Material st. st., hastelloy, titanium
    Max. pressure30 bar
    Max.temperature150°C
    For conductive liquids (>20 mikroS/cm)
  • Conductive Suspended Ektrode NEH
    For conductive liquids
    Contact 5 contacts via relays
    ConnectionG 1/2, G 11/2 male ½ NPT, 11/2 NPT male
    Material st. st., hastelloy, titanium
    Max. pressure 6 bar
    Max.temperature150°C
    For conductive liquids (>20 mikroS/cm)
  • Continuous Level Probe LNP
    Potentiometric principle
    For viscous, pasted, strong adhessive medias
    Measuring length 200...2000 mm
    Connection G 1, 1" NPT, G1 for hygenic sleeve LZE
    Material st.st. 1.4404 / PEEK
    Max. pressure 10 bar
    Max. temperature 120°C (short time 150 °C)
    Accuracy ± 1% FS
    Output 4-20 mA
  • Deep-Well Probe NTB
    Measuring range 0-1...0-200 mWc
    Material st. st., cable polyurethane
    Max. pressure 3x range end, max. temperature
    Accuracy ± 0,5 % FS
  • Diaphragm Level Indicator NPF
    Measuring range 0-600...0-6000 mm Wc
    Connection G ½ AG
    Material st. st.
    Max. pressure 1,3 x max. range, max. temperature
    Accuracy +/- 1,6 % FS
    Option contacts
  • Differential Pressure Gauge PAD
    Measuring range 0...41370 kPa
    Connection ¼ NPT, ½ NPT
    Housing Material st. st.
    Accuracy ±0,075% of meas. range
  • Digital Panel Indicators DAG
    Programmable, 4-digit LED
    Dimensions 96x48, 96x24, 72x36, 48x24,
    Input temperature, frequency, current, voltage
    output 0(4)-20 mA, 0-10 V
    Options sensor supply, contacts, min/max.-memory
  • Dual Magnet Float Level Switch NGS
    For liquids
    Contact 1 micro switch
    Connectionsquare flange, G 2, 2" NPT
    DIN-flange DN80, DN100
    Material st. st. 1.4571
    Max. pressure 25 bar
    Max.temperature250°C
    Liquid density ab 0,7 g/ml
    Certificates ATEX, Germanischer Lloyd
  • Electrode relay for conduct.level switches NE-104,-304
    for conductive level switches model NES, NEW, NEH
    output 1 or 2 limit switches
    min/max. controllers
    power supply 24, 110, 230 VAC
    mounting standard rail
  • Float Level Switch NSP-S
    For liquids
    Contact 1 micro switch
    Connection cable gland G1, G2
    MaterialPolypropylen
    Max. pressure1 bar
    Max.temperature85°C
  • Float Transducer-Reed Chain NM
    Measuring length max. 6 meters
    Connection R 3/8...R 2
    DIN-flange DN 50...DN 100
    Material st. st., PVC, PPH, PTFE,PE
    Max. pressure PN 20, Max. temperature
    Accuracy 0,5 % for L=2 m
    Output resistor, 4-20 mA
  • Hygenic Mounting Systems LZE
    EHEDG-and 3A-certified
    Connection sensor G 1/2, G 3/4, G1, M12x1,5
    Connection prozess weld on sleeve, ball sleeve, collar sleeve, Triclamp, varivent, clamp
    Material st.st. 1.4404
    Max. pressure 10 bar
    Max. temperature 250°C
  • Level Indicator acc. Archimedes principle BA
    Measuring length Max. 2x 6 meters (dependent of density)
    Connection DIN-flange
    Material st. st. , Hastelloy
    Max. pressure 40 bar
    Max. Temperature -40...+250 °C (option 300 °C)
    Accuracy ± 5 mm of meas. Value
    Mech. pointer indication
    Option transmitter 4-20 mA, contacts, ATEX, Hart, Profibus-PA
  • Level Modul for Conductive Level Probes, LNR
    for conductive level switches
    output 1 PNP
    power supply15...36 VDC
  • Level Switch NV
    For liquids
    Contact 1 reed switch
    ConnectionG ¾ male, ¾ NPT, M27x1,5
    Materialbrass, st. st.
    Max. pressure 16 bar
    Max.temperature110°C
    Liquid density from 0,7 g/ml on
  • Level Switch RFS
    For liquids
    Contact 1 reed switch
    Connection ½ NPT
    Material st. st. 1.4305
    Max. pressure 5 bar
    Max.temperature120°C /ATEX
    Liquid density from 0,7 g/ml
    Option ATEX
  • Limit contact for Bypass -Meter NBK-R
    bistable changeover contact
    max. temperature 100 °C
    electr. Connection cable
  • Liquid Level Switch NWS
    For liquids
    Contact 1 Electronic switch
    ConnectionG 3/4, G1 male, ¾ NPT, 1 NPT male,
    TriClamp DIN 32676, hygenic DIN 11851
    DIN-flange DN25, DN50;ANSI-flange
    Material st. st. 1.4404
    Max. pressure45 bar
    Max.temperature130°C (150 °C CIP-cleaning)
    Viscosity up to 5000 mm²/s
  • Magnetic Level Switches N
    For liquids
    Contact max. 4 reed switches
    ConnectionG 1/8...G 2 male, flange
    Material brass, st. st., PVC-U, PP, PTFE
    Max. pressure 100 bar
    Max.temperature150°C
    Liquid density from 0,5 g/ml on
  • Magnetic Level Switches for Side Installation NS
    For liquids
    Contact max. 4 reed switches
    ConnectionG 3/8...G 2 male, flange
    Materialbrass, st. st., PVC-U, PP
    Max. pressure 100 bar
    Max.temperature150°C
    Liquid density ab 0,6 g/ml
  • Magnetostrictive Level Meters NMT
    Measuring length 300-4000 mm
    Connection G 2, 2" NPT AG
    Material st. st.
    Max. pressure PN 10, Max. temperature
    Accuracy +/- 1 mm
    output 4-20 mA
  • Membrane Level Monitor NMF
    For bulks
    Contact 1 micro switch
    Connection circular flange
    Material membrane
    Retaining ring steel, stainless steel, aluminium
    Max. pressure 0 bar
    Max. temperature 200°C
  • Microwave Level Switch LNM
    As well for non conductive liquids
    insensitive to foam and adhesions
    Connection G 1/2, M12x1,5;
    hygenic mounting system (EHEDG)
    hygenic DIN 11851, Tri-Clamp, weld on sleeve
    Material st.st. 1.4404 / PEEK
    Max. pressure 10 bar
    Max. temperature 100 °C (CIP 150°C)
    Contact Open Collector, PNP, 50 mA
  • Mini Bypass Level Indicator NBK-M
    Measuring length Max. 3 meters
    Connection DIN-flange DN 10...DN 25
    ANSI-flange 1/2"... 1"
    Material st. st. 1.4571
    Max. pressure PN 40/300 lbs, max. temperature
    Accuracy transducer +/- 1 mm
    Option transmitter 4-20 mA, contacts
  • Optical Level Sensor OPT
    For liquids
    Contact 1 open collector
    Connection G ½ male, M14
    Material polypropylene, st. st.
    Max. pressure 10 bar
    Max. temperature 85°C
  • Over-Head Level Indicator NBK-04
    Measuring length max. 4 m
    Connection DIN-flange DN 50/65
    ANSI-flange 2" / 21/2"
    Material st. st. 1.4571 (316 TI)
    Max. pressure PN 16, Max. temperature
    Accuracy transducer +/- 1 mm
    Options transmitter 4-20 mA, contacts
  • Over-Head Level Indicator NBK-04 with ATEX
    Measuring length max. 4 m
    Connection DIN-flange DN 50/65
    ANSI-flange 2" / 21/2"
    Material st. st. 1.4571 (316 TI)
    Max. pressure PN 16, Max. temperature
    Accuracy transducer +/- 10 mm
    Options transmitter 4-20 mA, contacts
    Certificates ATEX
  • Pendulum Level Limit Switch for bulks PLS
    Electrodes max. 2 m
    Contact 1 micro switch (max. 250 Vac, 3A)
    Connection circular flange, diam.=142 mm, aluminium
    Material Electrodes aluminium
    Max. pressure -0,1 ...+0,5 bar
    Max. temperature +80 °C
    Option ATEX
  • Plastic Level Switch NKP
    For liquids
    Contact 1 reed switch
    ConnectionG 1/2A female, ½ NPT, M16
    MaterialPolypropylen, PVDF
    Max. pressure 10 bar
    Max.temperature100°C
    Liquid density from 0,6 g/ml on
  • Radar Level Meter NRM
    Measuring range 0,2...70 m
    Connection G 1½, 1½ NPT, flange DN 50...150
    Material Connection st. st.
    Max. pressure 160 bar,
    Max. temperature 400 °C
    Accuracy ±3 mm
  • Rotating Vane Level Monitor NIR
    For bulks
    Contact 1 micro switch
    Connection G 1, G 1 ½ male, roand flange
    Material shaft/Rotor
    Max. pressure 0,5 bar
    Max .temperature 80 °C
  • Rotating Vane Level Monitor NIR-8
    For bulks
    Contact 1 micro switch
    Connection G 1, G 1 ½ male, roand flange
    Material shaft/Rotor
    Max. pressure 0,5 bar
    Max .temperature 200 °C
  • Ultrasonic Level Meter NUS
    Measuring range liquids up to 8 m Solids/bulks up to 3,5 m Connection
  • Ultrasonic Level Switch NQ
    For liquids
    Contact 1 electronic switch
    ConnectionG 1male
    Material st. st.
    Max. pressure70 bar
    Max.temperature125°C
  • Universal Indicators ADI-B…F
    Indicator bargraph
    Input current ,voltage, frequency
    Housing 116x116x123 mm
    Option analogue-, frequency output, contacts, sensor supply
    Mounting wall- or pipe mounting
  • Vibrating Level Switch NVI
    For powder, granulate
    Contact 1 relay
    Connection G 1 1/2, 1 ½ NPT male
    Material st. st. 1.4571
    Max. pressure 25 bar
    Max.temperature 160 °C
  • Vibrating Level Switch SOLIVIB NSV
    For powder, granulate
    Electrodes max. 3 m
    Contact 1 relay (max. 250 VAC, 1A), 25 VA
    Connection G 1 ½ male
    Material st. st. 1.4305 (303)
    Max. pressure pressureless
    Max.temperature 80 °C
    Power supply 24, 110, 230 VAC, 18...36 VDC
    Certificates ATEX

Temperature

  • Bi-metal Thermometer TBI-I
    Measuring range -30 ... +50 up to 0 ... 500 °C
    Connection back or bottom
    G ½ AG, st. st.
    Housing Material st. st.
    Diameter of housing 63, 80, 100 mm
    Accuracy class 1,0
    Option mark pointer, gliding pointer
  • Capillary Thermometer Nitrogen Filled TNF
    Measuring range -20 ... +40 up to 0... 600 °C
    Connection back or bottom
    G ½... G1, ½ NPT...1" NPT, TriClamp,
    aso.
    Housing Material aluminum or st. st.
    Diameter of housing 63, 80, 100,160 or 250 mm
    Accuracy class 1,0 or 1,6
    cCpillary connection up to 100 m
    Option contacts, Max. pointer, oil filling
  • Contact Resistance Thermometers TWA
    Measuring range -20 ... +260 °C
    Housing Material brass, st. st.
    Sensor Pt 100, 2-wire, class B
    Cable PTFE, silicone
  • Digital Panel Indicators DAG
    Programmable, 4-digit LED
    Dimensions 96x48, 96x24, 72x36, 48x24,
    Input temperature, frequency, current, voltage
    output 0(4)-20 mA, 0-10 V
    Options sensor supply, contacts, min/max.-memory
  • Digital Thermometer DTM
    Measuring range -30 ... +50 up to 0...400 °C
    Connection back or bottom
    G ½... G1, 1/2"... 1" NPT
    Housing Material st. st., back polyamides
    diameter of housing 100 mm
    Accuracy class 0,5
    Option anlaogue output, up to 2(4) contacts,
    peak memory, RS 232
  • Frost Predection and Capillary Thermostat TEA-F, -K
    Switching range -30 ..+30 up to +50... +120, adjustable
    ConnectionG ½ or connection plate
    Material plastic or steel (housing)
    copper (probe)
    Micro switch SPDT, 24-250 VAC, 15 (8) A
    single or double contact
  • Glass Thermometer for Machines TGL
    Measuring range -60 ... +40 up to 0 ... 200 °C
    Connection G ½ or ½ NPT, brass
    Housing Material aluminum
    Housing length 110, 150 or 200 mm
    Accuracy class 1,0
  • Head Mounted Transmitter TUM-K
    Measuring range fixed or programmable
    Input Pt 100, thermocouples
    output 4-20 mA
    Supply 6,5...32 VDC
  • Immersion/ Insertion Resistance Thermometers TWE-6,-7,-8
    Measuring range -20 ...+350 °C
    Bulb Material st. st.
    Sensor Pt 100, 2,3 or 4--wire, class B
    Cablest.st. braided, PTFE, PVC
  • Immersion/Insertion Thermocouples TTE-6/-8
    Measuring range 0 ... +600 °C
    Bulb Material st. st.
    Sensor FeCu-Ni, NiCr-Ni, class 2
    Cable st.st. braided, PTFE
  • Infrared Hand-Held Thermometer TIR-HN
    Non- contact temperature measurement
    Measuring range -20 ... +500 up to -32 ... 900 °C
    Measuring Accuracy ± 1 % up to ±2 % of m. value
    Option analogue output, RS 232, data memory,
    Laser pointer, statistical functions
  • Infrared Thermometer (fixed installation) TIR-SA
    Measuring range 0 ... 120 up to 100 ... 500 °C
    Housing Material st. st.
    Accuracy class ± 1,5 % of m. value (min 2,5 °C)
    Supply voltage 18-30 VDC
    output thermic voltage Typ J or K, or
    10 mV/°C
  • Insertion Resistance Thermometers TWE-1
    Measuring range -20 ... +200 up to .-20... +600 °C
    Connection G ¼, G ½, M10x1
    Bulb Material st. st.
    Sensor Pt 100, 2,3 or 4-wire, class B
    Cable st.st. braided,silicone, head Form MA
  • Insertion Temperature Sensors with Transmitters TMA
    Measuring range -200 ... + 600 °C
    Connection G ½, ½ NPT fixed or adjustable
    Bulb Material st. st.
    Sensor Pt 100, 2-wire, class B
    Electrical connection plug DIN 43 650
    Output 4-20 mA
    Options plug-on display Typ AUF
  • Pipe Temperature Sensor for Reliable Dead-Zone-Free TWP
    Measuring range-20 ... +200 °C
    Connection Hygenic connection, Triclamp
    Pipe st. st. DN 15..DN 80
    Sensor Pt100
    Head B or field housing
  • Precision Hand-Held Thermometer HND-T125
    Measuring range -65... +199,9°C, -65..+1150°C
    Probe Thermo couples K
    Accuracy ± 0,05 %, ±0,1 % of m. value
    Supply 9 V battery
    Holding Function, min/max. -memory, °C/°F
  • Predection Pipes for Thermometer TSH
    Connection G ½...G 1, welded 18mm...28 mm
    Material st. st.
    Max. pressure 25 bar
  • Resistance Temperature Probe with Connection Box LTS-A
    Pt100, class A acc. DIN IEC 751
    Range -50...+250 °C
    Connection G 1/2, M12 for hygenic sleeve LZE
    Material st.st.
    Max. pressure 10 bar
    Option head mounted transmitter 4-20 mA, fast responding sensor tip, longer neck for higher temperatures
  • Resistance Thermometers for harsh operational conditions TNK
    for diesel engines in railway or ship building
    Measuring range -80 ... +150 °C
    Connection G ½.. ½ NPT, M18x1,5
    Predective tubes brass, bronze (sea-water resistant), st. st.
    Sensor Pt 100, Pt 1000, Ni 100, 2,3 or 4-wire
    Certificates GL
  • Resistance Thermometers TWL
    Measuring range -200...+750 °C
    Connection thread, flange, weld-on sleeve
    Bulb Material st. st.
    Sensor Pt 100, 2,3 or 4-wire, class A or B
    Option head mounted transmitter 4-20 mA, HART, Profibus, Fieldbus
  • Resistance Thermometers with Bayonet Lock TWM
    Measuring range -20... +350 °C
    Connection bayonet with spring pressure
    Bulb Material st. st.
    Sensor Pt 100, 2,3 or 4--wire, class B
    Cable st.st. Braided
  • Rod and Air-DuctThermostat TEA-L, -S
    Switching range -15 ..+30 up to +50... +120, adjustable
    Connection G ½ or connection plate
    Material plastic (housing)
    copper or st. st. (probe)
    Micro switch SPDT, 24-250 VAC, 15 (8) A
    single or double contact
  • Room and Surface Thermostat TEA-R,-A
    Switching range -30 ..+30 up to +50... +120, adjustable
    Material plastic (housing)
    copper or st. st. (probe)
    Micro switch SPDT, 24-250 VAC, 15 (8) A
    single or double contact
  • Room Thermometers TWL-ST
    Measuring range -20...+60 °C
    Connection wall mounting
    Sensor Pt 100, class A or B, 4-20 mA
  • Screw-In Resistance Thermometer according to DIN TWD-B9
    Protection pipe form B
    Measuring range -80 ... +600 °C
    Connection G ½
    Material of predective tubes steel, st. st.
    Sensor Pt 100, 2,3 or 4--wire, class B
    Option head mounted transmitters 4-20 mA
  • Screw-in Thermocouples TTE-1
    Measuring range -200 ... +600 °C
    Connection G ½, M10x1
    Bulb Material st. st.
    Sensor FeCu-Ni, NiCR-Ni, class 2
    Cable st.st. braided
  • Shaft Thermometers according to DIN 16205 TNS
    Measuring range -20 ... +40 up to 0 ... 600 °C
    Connection back or bottom
    G ½... G1, ½ NPT...1" NPT, TriClamp, and so on
    Housing Material aluminum or st. st.
    Diameter of housing 63, 80, 100,160 or 250 mm
    Accuracy class 1,0 or 1,6
    Option contacts, gliding pointer, oil filling, and so on
  • Sheath Resistance Thermometers TWM
    Measuring range -20 ... +600 °C
    Bulb st. st., D= 1,5...6,0 mm
    Sensor Pt 100, 2,3 or 4--wire, class B
    Cable silicone, head form MA, LEMOSA-connector
  • Sheath Thermocouples TTM
    Measuring range -50 ... +1100 °C
    Bulb st. st., inconel, D= 0,5...6,0 mm
    Sensor FeCu-Ni, NiCr-Ni, class 2
    Connection cable made of silicone, flat connector, head
    Form MA
    Accessories connections
  • Stem Thermometer for Diesel Engines TND
    Measuring range 0 ... +600 up to 0 ... 800 °C
    Connection bottom, G ½, G ¾
    Housing Material steel or st. st. with silicone filling
    Diameter of housing 63, 80, 100 mm
    Accuracy class 1,6 (63, 80 mm), 1,0 (100 mm)
    Option damping spring
  • Temperature sensor TDA
    Measuring range -50 ... +125 °C
    ConnectionG 1/2, G3/4 male, 1/2, ¾ NPT st. st.
    Material st.st.
    Indication 3-digit LED
    Electrical connection plug M12x1 or cable
    Supply 24 VDC
    analogue output 0(4)-20 mA, programmable,
    Semiconductor PNP/NPN, digital display
    Accuracy ±0, 5 °C (for range -10...+85 °C)
  • Temperature Sensor TSA
    Measuring range -40 ... 150 °C
    Connection G ¼... G 1
    Connection Material brass or st. st.
    output NTC or Pt 100
  • Temperature Switch TWR
    Switch points +30 ... +120 (in 5 or 10 °C steps)
    fixed
    ConnectionG ¾ male, brass or st. st.
    Electrical connection plug DIN 43 650
    Switching Accuracy 30..+90 °C ± 5 °C
    100-120 °C ± 7 °C
    Hysteris max. 20 °C
  • Temperature Switch-Digital TDD-1,-3,-5,-7
    Switch points -20 ... +125 °C, adjustable
    ConnectionG ½, G¾ male, ½, ¾ NPT st. st.
    Indication 3-digit LED
    Electrical connection plug M12x1 or cable
    Supply 24 VDC
    Contact 1 or 2 semiconductors PNP/NPN
    N/O or N/C adjustable
    Switching Accuracy ±0, 5 °C (-10...+85 °C)
  • Thermal Reed Switches TRS
    Switch points +10 ... +120 (in 5 bzw. 10 °C Schritten)
    fixed
    ConnectionG ¼...G 1 male, brass or st. st.
    Electrical connection cable
    Switching Accuracy ± 3 °C
    Hysteresis < 7 °C
  • Thermocouples (according to DIN) TTD
    Predection tube Form AM, AK, B, BM, MA
    Measuring range -200.. +600 up to -200... 1150 (1200) °C
    Connection G ½, sliding flange
    Material of predective tubes steel, st. st., ceramics
    Sensor FeCu-Ni, NiCr-Ni, class 2
    Option head mounted transmitter 4-20 mA
  • Thermocouples TTL
    Measuring range -200...+1600 °C
    Connection thread, flange, weld-on sleeve
    Material of predective tubes steel, st. st., ceramics
    Sensor FeCu-Ni, NiCr-Ni, class 1 or 2
    Option head mounted transmitter 4-20 mA
  • Thermocouples with Bayonet Lock TTE-5
    Measuring range0 ... +400 °C
    Connection bayonet with spring pressure
    Bulb Material st. st.
    Sensor FeCu-Ni, NiCr-Ni, class 2
    Cablest.st. Braided
  • Thermostats for industrial Applications TER
    Switching range -20 ..+20 up to +80... +130, adjustable
    Material die-cast metal (housing)
    copper, brass or st. st. (probe)
    Micro switch SPDT Max. 250 V
    8 (5) A bei 250 VAC
    1 A bei 24 VDC
  • Transmitter for DIN-Rail Mounting TUM-S
    Measuring range fixed or programmable
    Input Pt 100, thermocouples
    output 4-20 mA
    Supply 6,5...32 VDC
  • Universal Bussystem KOBUS
    as plug-on display, 4-digit, red LED
    up to 240 sensors, BUS-length max. 1km
    for transmitters with (0)4-20 mA, 0-10 V or
    0.5..1000 Hz output and plug DIN 43 650
    software for indication, datalogger, configuration

Flow

  • Air Eliminator ZAL
    Filter grade 40...200 µm
    Connection Flansch ANSI 1"...4"
    Max. pressure 10 bar
    Max. temperature 70 °C
  • Batching electronic ZED-D
    Display 2x LC-Display, alphanumeric,
    8-digit (quantity), 5-digit (batching quantity)
    Dimensions 96x96 or 116x116 (field housing)
    Input 0,2...2000 Hz (5-24 VDC)
    Control Input Start, stop and reset function
    Output 0(4) - 20 mA, 2x change-over contacts
    Power Supply 24 VDC or 90-250 VAC
    Sensor Supply 12V/ 15 V
    Menu guided, password, teach-in operation
  • Buffle Flap Flow Flowmeter/-switch DWD
    Measuring range 1-10 L/min ... 360-3600 m³/h water
    Connection G 3/8...G 2, 3/8 NPT..2 NPT,
    flange DN 10..DN 50, weld on flange. up to
    NW 500
    Material brass, st. st., PVC
    Max. pressure PN 25
    Max. temperature 120 °C
    Accuracy ± 1,5 % FS
  • Calorimetric Flowmeter,-switch DVK
    Range 1-10...600-12 000 L/min air
    Connection G ¼...G 2
    Material connection
    Max. pressure 10 bar
    Max. temperature 50 °C
    Accuracy ± 5% v. ME
    LED-Indication, 2 open collector PNP, totalizing function
  • Calorimetric Indicator/Switch KAL, KAL-E
    Sensor and Electronic seperate
    Switching range 4 cm/s ... 2 m/s
    Connection G ¼... G 11/2, ¼ NPT...1 ½ NPT
    Material brass, st. st.
    Max. pressure 100 bar
    Max. temperature 80 (120) °C
    Repeatability approx. 2 %
    Relays for flow and temperature
    Option Ex II(1)G[EExia] II B T4
  • Calorimetric Indicator/Switch KAL-D
    Switching range 0,04 m/s ... 2 m/s
    Connection G ¼, G ½, ¼ NPT, ½ NPT, M12 x 1
    Material stainless steel
    Pmax 40 bar ( 140°C CIP, device not in function)
    Tmax 80°C
    Repeatability +/- 2 %
    LCD-display, switching output
  • Calorimetric Indicator/Switch KAL-K
    Switching range 4 cm/s ... 2 m/s
    Connection G ¼...G 3/4, ¼ NPT...¾ NPT, M12x1, Tri Clamp
    Material st. st.
    Max. pressure 100 bar
    Max. temperature 80 °C
    Repeatability aprox 2 %
    LED-chain, relays
  • Counter and Dosing Electronic ZOD
    Display 2x LC-Display, alphanumeric,
    Power Supply 24 VDC or battery
  • Counter electronic ZED-Z
    Display 2x LC-Display, alphanumeric,
    8-digit (quantity), 3 or 4 digit (flow)
    Dimensions 96x96 or 116x116 (field housing)
    Input 0,2...2000 Hz (5-24 VDC)
    Control Input reset function
    Output 0(4) - 20 mA, 2x change-over contacts
    Power Supply 24 VDC or 90-250 VAC
    Sensor Supply 12V/ 15 V
    Menu guided, password, teach-in operation
  • Digital Panel Indicators DAG
    Programmable, 4-digit LED
    Dimensions 96x48, 96x24, 72x36, 48x24,
    Input temperature, frequency, current, voltage
    output 0(4)-20 mA, 0-10 V
    Options sensor supply, contacts, min/max.-memory
  • Displacer Flowmeter/-switch-All Metall-Mounting Position Independent BGF
    for horizontal mounting
    Measuring -/switching range
    10 - 100 ... 4.000 - 40.000 L/h water
    0,3 - 3,0 ...110 -1100 Nm³ /h air;
    Connection flange DN 15 ... DN 100, ANSI 3/4"...4"
    Material st. st. 1.4404, option PTFE-lining
    Max. pressure PN 40 (16) bar, on request max PN 600 bar
    Max. temperature -40...+200 °C (-40...+350°C on request)
    Accuracy ± 2 % of meas. value
    Options contacts, analogue output, totalizer,
    Hart, Profibus PA, ATEX
  • Displacer Flowmeters/-switch-All Metall SMO/SMW
    Flow downward or horizontal
    Switching range0,2-3...10-120 L/min water
    Connection G ¼..G 1 female
    Material brass, st. st.
    Max. pressure 250 bar (brass), 350 bar (st. st.)
    Max. temperature 100 °C
    Accuracy ± 5 % FS
    Reed contact
  • Displacer Flowswitch-All Metal SMN
    Switching range 1 - 100 L/min water
    Switch point at approx .1 L/min falling
    Connection G1 female
    Material brass or st. st.
    Max. pressure 250 bar (brass), 350 bar (st. st.)
    Max. temperature 120 °C
    Accuracy ± 5 % FS
    Reed contact
  • Dosing Unit-Oval Gear Wheel Flowmeter for Additives DOP
    Measuring range 0,01-1 ... 0,25-10 L/min liquid
    Connection 3/8 NPT
    Material aluminum
    Max. pressure 20 bar
    Max. temperature 100 °C
    Accuracy ±0,5% of reading
  • Dosing Unit-Oval Gear Wheel Flowmeter-Mechanical DOL
    Measuring range 0,5-36 L/h...150-2500 L/min liquid
    Connection G 1/8...G 4 female
    Material aluminum
    Max. pressure 400 bar
    Max. temperature 120 °C
    Accuracy ± 0,2...1% of reading
    Viscosity range 0-1200 cP
    Pulse output
  • Dosing Unit-Rotating Vane Flowmeter DOB
    Measuring range 1-70 L/min water
    Connection G ¾, ¾ NPT
    Material brass
    Max. pressure 10 bar
    Max. temperature 80 °C
    Accuracy ± 1,5% of reading
  • Dual-Ring Piston-Pendulum-Flowmeter-Low Volume LFM
    Measuring range 0,005-0,25 L/min water
    Connection G 1/8 female and swagelock 6mm
    Material st. st.
    Max. pressure 100 bar
    Max. temperature 70 °C
    Accuracy ± 2,5% of m. value
    Pulse output
  • Electromagnetic Flowmeter DMH
    Measuring range
    Connection flange DN 15...DN300
    Material case lining soft rubber, Ebonite, PTFE, PFA, PA1
    Max. pressure PN 40 bar
    Max.temperature-20...+150°C
    Accuracy± 0,3 % of m. value ±0,01%xQmax.
    Output pulse-/analogue output, status display, totalizer, Hart
  • Electromagnetic Flowmeter for Partly Filled Systems DUW
    Measuring range 0-6 m/s
    Max.temperature 50 °C
    Accuracy ±1,0% f.m. value
  • Electromagnetic-Insertion PIT
    Measuring range 1-10 m/s (0,5- 5 m/s st.st.-version)
    Weldable connection sleeves for DN 150..2000
    Material st. st. (1.4571,1.4404)
    PTFE or PFA- tube lining up to DN 600
    Max. pressure 16 bar, 40 bar (PTFE, PFA-lining)
    Max.temperature
    -40..100°C, -20..80°C (PVDF) , -40...+150 °C (PFA)
    Accuracy ± 1,5 % of m. value plus ± 0,,5 % FS
    Transmitter relays, analogue/pulse output, digital display,
    Hart, Profibus, ATEX, NEPSI
  • Electromagnetic-Switch MIK-..S3
    Measuring range 0,01-0,5 ...35-700 L/min liquid
    Connection G ½..G 2 ¾ male
    Material PPS/st. steel PVDF/Hastelloy, Tantalum
    Max. pressure 10 bar
    Max.temperature80°C
    Accuracy± 2 % FS
    Switchpoint
  • Flap Flowmeter/-switch TSK
    Measuring range 1,5-10....200-1.500 m³/h. water
    Connection wafer DN 50...DN 500
    Material steel, st. st., Polypropylene, PTFE, Hastelloy
    Max. PN 40, PN16 (DN100-200), PN10 (from DN250)
    Max. temperature -40..+200 °C (-40...+300°C on request)
    Accuracy ± 2 % (1,0% ) FS
    Options contact, 4-20 mA, ATEX,
    Hart-Protokoll, Profibus PA
  • Flow Indicator w. Rotor and Self-cleaning mech. DAA
    Indicating range 0,4 - 4 L/min ... 8 - 100 L/min water
    Connection G ¼...G1 ½ female, ¼...1 ½ NPT
    Material brass, st. st.
    Max. pressure 16 bar
    Max. temperature 100 °C
    Viscosity 1 - 150 mm²/s
  • Flow Indicator with Ball DAB
    Connection G 3/4...G 3 female
    Material bronze, ball
    Max. pressure 6 bar
    Max. temperature 100 °C
  • Flow Indicator with Ball DKB
    Indicating range 0,05-15 L/min...0,18-105 L/min water
    ConnectionG 1/8...G 1 female, 1/8...1 NPT female
    Material brass, ball
    Max. pressure 6 bar
    Max. temperature 120 °C
  • Flow Indicator with Drip Tube DAT-1
    Connection G ¼... G2, ¼...2 NPT
    Material grey cast iron, cast steel, st. st.;
    Max. pressure PN 40
    Max. temperature 280 °C
  • Flow Indicator with Flap and Scale DAZ
    Indication range 2,1 - 17 L/min ... 2,1 - 24 L/min water
    Connection G ½... G 1
    Material red cast iron
    Max. pressure 16 bar
    Max. temperature 200 °C
  • Flow Indicator with Flap DAK-1
    Connection G ¼...G 2 female, ¼...2 NPT
    Material grey cast iron; cast steel; st. st.
    Max. pressure PN 40
    Max. temperature 280 °C
  • Flow Indicator with Rotor DAF-1
    Indicating range 0,03 - 0,1 L/min ...5 - 150 L/min water
    Connection G 1/8 - G 1 1/2
    Material brass, st. st., trogamide, polysulfone
    Max. pressure 10 / 16 bar
    Max. temperature 110 °C
  • Flow Indicator with Rotor DAH
    Indicating range 0,4 - 4 L/min ... 8 - 100 L/min water
    Connection G ¼... G 1 ½ female, ¼...1 ½ NPT
    Material brass, st. st.
    Max. pressure 16 bar
    Max. temperature 100 °C
  • Flow Indicator with Rotor DAR-1
    Connection G ¼...G 2 female; ¼..2 NPT
    Material grey cast iron; cast steel; st. st.
    Rotor plastic or PTFE
    Max. pressure PN 40
    Max. temperature 260 °C (with PTFE-rotor)
  • Flow Indicator with Rotor DIG
    Water 5 -12 L/min..38 -80 L/min
    Connection G1/8...G1, 1/8 ...1 NPT
    Housing aluminium-bronze, stainless steel, PP
    Pmax 16 bar
    Tmax 80°C
  • Flow Indicator with Rotor DIH
    Indicating range 0,2 - 0,5 L/min ... 1 - 50 L/min water
    Connection G 3/8, G 1 female
    Material brass, st. st., POM
    Max. pressure 16 bar
    Max. temperature 80 °C
  • Flow Indicator with Rotor DKF
    Indicating range 0,14-2 L/min...1,8-83 L/min water
    Connection G 1/8... G 1, 1/8...1 NPT
    Material brass, Rotor
    Max. pressure 6 bar
    Max. temperature 120 °C
  • Flow Indicator-Sight Glass UFJ
    Connection G ¼...G 2 female
    Material st. st., PVC
    Max. pressure 10 bar
    Max. temperature 100 °C
  • Flow, Humidity and Temperature Hand-Held Measuring Unit HND-F115
    For weight moisture or relative humidity
    Measuring range 0(4) -100 % rel. humidity
    Accuracy ± 0,1 / 0,2 % of rel.humidity
    Supply 9 V battery
    Holding Function, min/max. -memory, alarm,
    data logger, output 0-1 V, RS 232
    Option temperature-, flow measuring
  • Gear Wheel-Meter DZR
    Measuring range 0,008-2 L/min ...3-700 L/min liquid
    Connection G 1/8...G 1 female
    Material continuous cast, st. st.
    Max. pressure 400 bar
    Max. temperature 150 °C
    Accuracy ± 0,3% ... ±1 % of m. value
    Viscosity range max. 30.000 mm²/s
    Pulse output
  • Gear Wheel-Meter KZA
    Measuring range 0,02-4 L/min ...1-200 L/min liquid
    Connection G ¼, G 1 female
    Material aluminum
    Max. pressure 160 bar
    Max. temperature 120 °C
    Linearity ± 0,3 %...± 3 % of m. value
    Viscosity range max. 4000 mm²/s
    Pulse output
  • Low Volume Turbine Wheel Flowmeter SFL
    Measuring range 0,5-20 L/min water
    Connection G 3/8
    Material PVDF, st. st.
    Max. pressure 250 bar
    Max. temperature 90 °C
    Accuracy ±1% of m. value
    Pulse output
  • Manifold Valves for Multiple Installation BVB
    Max. flow 24 L/min per group
    Connection G ½ female
    Material aluminum
    Max. pressure PN 64
    Max. temperature 100 °C
    Max. 8 fold
  • Mass Flowmeter Coriolis TM
    high accuracy and special versions
    Measuring range 0,8 - 8 kg/h ... 4.000 -40.000 kg/h
    Connection flange DN 10 - DN 100;ANSI ½ -3"
    JIS, NPT, special acc. customers specification
    Material st. st., Hastelloy, Monel, Tantal,
    Nickel, special materials
    Max. pressure PN 40 bar (up to 900 bar on request)
    Max. temperature -90... +260 °C
    Accuracy(liquids) ± 0,1 (0,05) % of m. value ± zero point-stability
    (gases) ± 0,15 % of m. value ± zero point-stability
    Transmitter Analog-, pulse output, digital display,
    Hart, Profibus, ATEX,FM,FMC,NEPSI
  • Mass Flowmeter Coriolis TME
    economical version
    Measuring range 20 - 200 kg/h ... 6.000 -60.000 kg/h
    Connection flange DN 10 - DN 80;ANSI ½ -3"
    Material st. st. (1.4571 oder 1.4404)
    Max. pressure PN 40 bar
    Max. temperature -40... +180 °C
    Accuracy (liquids) ± 0,15 % of m. value ± zero point-stability
    (gases) ± 0,5 % of m. value ± zero point-stability
    Analog-, pulse output, digital display,
    Hart, Profibus, ATEX,FM,FMC,NEPSI
  • Mass Flowmeter Coriolis TMR
    ideal substitute for oval gear meter
    Measuring range 0 - 120.000 kg/h liquids
    0- 92.000 Nm³/h air
    Connection flange DN 50 - 100, ANSI 1 1/2"
    Material st. st., Tantal, Hastelloy, Monel, Zirkon
    Max. pressure PN 40 bar /300 lbs
    Max. temperature 40... +260 °C
    Accuracy± 0,1 (0,15 %) of m. value ± value ± zero point-stability
    Transmitter analogue-, pulse output, digital display,
    Hart, Profibus, ATEX,FM,FMC,NEPSI
  • Mass Flowmeter Coriolis TMU
    wide measuring span
    Measuring range 0,06 - 0,6 t/h ... 400 -2.200 t/h
    Connection flange DN 10 - DN 400;ANSI ½ -16"
    JIS, NPT, special acc. customers specification
    Material st. st. (1.4571 or 1.4404) , Hastelloy C-22
    Max. pressure PN 40 bar (higher on request)
    Max. temperature -40... +260 °C
    Accuracy(liquids) ± 0,1 (0,15%) % of m. value ± zero point-stability
    (gases) ± 0,5 % of m. value ± zero point-stability
    Analog-, pulse output, digital display,
    Hart, Profibus, ATEX,FM,FMC,NEPSI
  • Mass Flowmeter-Thermal KES
    Measuring range 0-4.7 .. 0-94 m/s air
    Connection plug-in version bis NW1000
    1/4"...8" NPT, DIN-flange DN25..DN200
    ANSI-flange 1"...8"
    Material st. st.
    Max. pressure 16 bar
    Max. temperature 175 °C
    Accuracy ± 1 % FS
    Analogue output, RS 232
  • Mass Flowmeter/Controller-Thermal DMS
    Measuring range 0-0.01 .... 0-200 NL/min air
    Connection1/4..1/2 F NPT
    1/8..1/2, 6,10,12 mm
    Material st. st.
    Max. pressure 35 bar
    Max. temperature 50°C
    Accuracy± 1 % FS
    2 outputs, 4-20 and 0-5,0-10,1-5 VDC
    digital display, regulator function
  • Mass-Flowmeter-Thermal DMW-A/B
    Measuring range 0,005-0,1...300-6000 NL/min air
    Connection pipe connection G ¼...G1
    Material aluminum, st. st.
    Max. pressure 10 bar
    Max. temperature 50 °C
    Accuracy ± 3 % FS
    Analogue output, option LC display, totalizer
  • Orifice Plate-Differential Pressure KPL
    Measuring span 1
    Connection DN 50...1600,
    Material steel, st. st., Hastelloy C, Titanium, Monel, Tantalum
    Max. pressure PN 100
    Max. temperature 560 °C
    Accuracy ±1,0% of reading
  • Oscillation-Meter/Switch DOG-1
    Range 0,2-20...160-16.000 m³/h air
    Connection flange
    Material cast steel, steel, stainless steel
    Pmax PN40 bar
    Tmax 120°C
    Accuracy +/- 1.5 % of measured value (air)
    Pulse & analogue output,
    digital display for flow measurement and counter
  • Oval Gear-Pulse Output DOM-..F4
    Measuring range 0,5-36 L/h...150-2500 L/min liquid
    Connection G 1/8...G 4 female
    Material aluminum
    Max. pressure 400 bar
    Max. temperature 200 °C
    Accuracy ± 0,2...1% of reading
    Viscosity range 0-1200 cP
    Pulse output
  • Oval Gear-Pulse Output OVZ-..I4
    Measuring range 0,1-2 L/min ...1,6-40 L/min liquid
    Connection G ¼...G ¾ female
    Material POM, aluminum
    Max. pressure 10 (40) bar
    Max. temperature 80 °C
    Accuracy ± 2,5% of m. value
    Viscosity range 10-800 mm²/s
    Pulse output
  • Paddle Bellow Flowmeter/-switch DWU
    Indication - /switching range 1-5 L/min ... 900-3600 m³/h water
    Connection G 3/8...G 2, flange DN 10..DN 50,
    weld-on flange up to NW 500
    Material brass, st. st.
    Max. pressure PN 10
    Max. temperature 100 °C
    Accuracy ± 3..±5 % FS
    Micro switch
  • Paddle Bellow Flowswitch DWN
    switching range 1-5 L/min ... 900-3600 m³/h water
    Connection G 3/8...G 2, flange DN 10..DN 50,
    weld-on flange up to NW 500
    Material brass, st. st., PVC
    Max. PN 10
    Max. temperature 100 °C
    Accuracy ± 3..±5 % FS
    Micro switch
  • Paddle Bellow Flowswitch FPS
    Switching range off
    on 0,6-1,1m³/h ...85,1-173 m³/h water
    Connection G 1 male for DN 25...200, or G ½ and G3/4
    Material brass; st. st.
    Max. pressure 11 bar (brass); 30 bar (st. st.)
    Max. temperature 120 °C
  • Paddle Switch PSR
    Switching range 2,3-4,7 L/min...47,6-67,2 L/min water
    Connection G ¼... G 1 ½, ¼...1 ½ NPT
    Material brass, st. st.
    Max. pressure 100 bar
    Max. temperature 110 °C
    Reed contact
  • Paddle Switch-Air LPS
    Switching range off
    on 2,5 m/s... 9,2 m/s air
    Connection square flange
    Material brass
    Max. pressure pressureless
    Max. temperature 85 °C
  • Paddle Switch-Polysulfone PPS
    Switching range 36...108 L/min water (rising)
    18...72 L/min water (falling)
    Connection G 1, 1 NPT for DN 32 ...DN 80
    Material polysulfone
    Max. pressure 10 bar
    Max. temperature 105 °C
    Adjustable accuracy ± 20 % FS
  • Paddle Torsion Meter/Switch DPT-..C3
    Measuring range 5-30 L/min ... 850-1900 L/min water
    Connection G 3/8...G 3, 3/8 NPT...3 NPT,
    Material aluminum/bronze, st. st.
    Max. pressure PN 40
    Max. temperature 80 °C
    Accuracy ± 3 % FS
  • Probe-Differential Pressure ANU
    Measuring span 1
    Connection DN 80...3000,
    Material steel, st. st., Hastelloy C, Titanium, Monel, Tantalum
    Max. pressure 40 bar
    Max. temperature 300 °C
    Accuracy ±2,5% of reading
  • Ring Piston Counter DRT
    Measuring range 10-500 ... 700-20 000 L/h oil
    Connection G ½...2, ½...2 NPT, flange DN 15...50, Tri-Clamp
    Material aluminium, st. st.
    Max. pressure 300 bar
    Max. temperature 150 °C
    Accuracy ±0,5...1% meas. value.
    Viscosity range 5-100 m²/s
    Pulse output, analogue output,
    Contacts, digital display
  • Ring Piston Counter-Pulse Output DRZ-..F
    Measuring -/switching range 6-420 L/h oil
    Connection G1/8, G ¼, 1/8 NPT, ¼ NPT
    Material brass
    Max. pressure 40 bar
    Max. temperature 80 °C
    Accuracy ± 1 % meas. value.
    Pulse output
  • Rotating Vane Flowmeter DOW
    Measuring range 1-70 L/min water
    Connection G ¾, ¾ NPT
    Material brass
    Max. pressure 10 bar
    Max. temperature 90 °C
    Accuracy ± 1,5% of reading
  • Rotating Vane Flowmeter-Insertion Version DOR
    Measuring range 0,36-6300 L/s water
    Connection G 1½, G 2, 1½ NPT, 2 NPT male
    Material st. st.
    Max. pressure 80 bar
    Max. temperature 200 °C
    Linearity ±1,5%
  • Rotating Vane-Flowmeter-Low Volume DTK
    Measuring range 0,05-0,6 ...1,0-12 L/min water
    Connection G 1/4, ¼ NPT
    Material st.steel
    Max. pressure 30 bar
    Max. temperature 80 (140) °C
    Accuracy ± 2 % FS
    Pulse output, analogue output
    Contacts, digital display
  • Rotating Vane-Low Volume KFF-1, KFG-1
    Measuring range 15-100 mL/min ...1-10 L/min water
    25-100 mL/min ...100-500 L/min air
    Connection G 1/8...G ½
    Material ryton, brass, PTFE
    Max. pressure 35 bar
    Max. temperature 50 °C
    Accuracy ± 3% FS
    Viscosity range low viscosity
    Pulse output, 0-5 VDC
  • Rotating Vane-Low Volume-Pulse Output DF-H
    Measuring range 0,08-0,5 L/min ...40-160 L/min water
    Connection G 1/8...G 1 1/2, flange DN 15..DN 50,
    Material brass, st. st., trogamide, polysulfone, PVDF
    Max. pressure 6/10/16/100 bar
    Max. temperature 80 °C
    Accuracy ± 2,5% FS
    Pulse output
  • Rotating Vane-Low Volume-Pulse Output DPL-..F5
    Measuring range 0,025-0,5 L/min ...1-25 L/min water
    Connection G ½ male or hose connector
    Material Polypropylene
    Max. pressure 10 bar
    Max. temperature 70 °C
    Linearity ± 1%
    Pulse output, frequency divider
  • Rotating Vane-Low Volume-Pulse Output DPM-..F5
    Measuring range 0,015-0,7 L/min ...0,05-5 L/min water
    connection G 1/8, G ¼, 1/8 NPT, ¼ NPT
    Material brass nickle plated, st. st.
    Max. pressure 16 bar
    Max. temperature 80 °C
    Accuracy ± 1 (2,5) % FS
    Pulse output
  • Rotating Vane-Pulse Output DFT-11
    Measuring -/switching range 0,2-2 L/min ...3-60 L/min water
    Connection G ¼...G ¾, ¼ NPT... ¾ NPT
    Material brass
    Max. pressure 16 bar
    Max. temperature 80 °C
    Accuracy ± 2,5 (5) % FS
    Pulse output
  • Rotating Vane-Pulse-Analogue Output DRG-..F, DRG-..L
    Measuring range 0,5-12 L/min ...10-140 L/min water
    Connection G 1/8... G 1, 1/8 NPT.. 1 NPT
    Material aluminum-bronze, st. st., Polypropylen
    Max. pressure 40 bar
    Max. temperature 80 °C
    Accuracy ± 3 % FS
    Pulse output, analogue output
  • Rotating Vane-Pulse-Analogue Output DRH-..F, DRH-..L
    Measuring range 0,2-0,8 L/min ...2,5-50 L/min water
    Connection G 3/8, G 1, 3/8 NPT, 1 NPT
    Material brass, st. st., POM, PVDF
    Max. pressure 100 bar
    Max. temperature 100 °C
    Accuracy ± 2,5 % FS
    Pulse output, analogue output
  • Screw Spindle-Meter OME
    Measuring range 0,2-10 L/min ...2-100 L/min liquid
    Connection G ½...G 1 female, flange DN 15..DN 25
    Material aluminum
    Max. pressure 40 bar
    Max. temperature 100 °C
    Accuracy ± 0,3% of m. value
    Viscosity range 1-5000 m²/s
    Pulse output
  • Screw Spindle-Meter OMG
    Measuring range 0,1-10 L/min ...50-5000 L/min liquid
    Connection G ½...G 6 female, flange DN 15..DN 100,
    Material continuous cast, st. st.
    Max. pressure 400 bar
    Max. temperature 200 °C
    Accuracy ± 0,3% of m. value
    Viscosity range 1-5000 m²/s
    Pulse output
  • Turbine Wheel Flowmeter TUV
    Measuring range 0,3-1,5 L/min ...35-400 L/minwater
    Connection G ¼...G 1 ½ female
    Material st. st.
    Max. pressure 100/400/640 bar
    Max. temperature 120 (350) °C
    Linearity ± 1% of m. value
    Viscosity range 1-30 m²/s
    Pulse output
  • Turbine Wheel Flowmeter-Counter Electronics DOT
    Measuring range 0,11-1,1 ... 700-7000 m³/h water
    Connection G ½...2, ½...2 NPT, flange DN 5...500
    Material st. st.
    Max. pressure 250 bar
    Max. temperature 120 °C
    Linearity ±0,5% of m. value
  • Turbine Wheel Flowmeter/-counter-Battery powered EDM
    Without power supply (lithium battery)
    Measuring range 4-40 L/min ...80-800 L/min water
    Connection G ½...G2
    Material nylon, brass, st. st.
    Max. pressure 10/20/100 bar
    Max. temperature 60 °C
    Accuracy ± 1,5 % FS
  • Turbine Wheel-Low Volume PEL-L
    Measuring range 0,006-0,1 L/min ...0,1-28 L/min water
    Connection R ¼, R ½, hose connector
    Material GN, PVC, PFA, st. st., titan
    Max. pressure 5..345 bar
    Max. temperature 70 °C (135 °C)
    Accuracy ± 1,25 % FS
    Pulse output
  • Turbine Wheel-Pulse Output DRS-..F5
    Measuring range 2,0-40 L/min water
    Connection G ½, G 3/4, ¾ NPT
    Material Noryl, Ultem, brass, st.st.
    Max. pressure 16 bar, 200 bar (brass, st.st.)
    Max. temperature 80 °C
    Accuracy ± 1,5 % FS
    Pulse output
  • Turbine Wheel-Pulse Output TUR-1
    Measuring range 0,2-5 L/min ...2,5-100 m³/h water
    Connection flange DN 25..DN 100
    Material PVC, PVDF
    Max. pressure PN 10
    Max. temperature 60°C (PVC), 70 °C (PVDF)
    Accuracy ± 1 % FS
    Pulse output
  • Turbine Wheel-Pulse-Analogue Output DPE-..F, DPE-..L
    Measuring range 7-30 L/min ...100-750 L/min water
    Connection G ½... G 3, ½ NPT...3 NPT
    Material aluminum/bronze, st. st.
    Max. pressure 40 bar
    Max. temperature 80 °C
    Accuracy ± 2,5 % FS
    Pulse output, analogue output
  • Turbine Wheel-Pulse-Analogue Output DRB-..F, DRB-..L
    Measuring range 5-30 L/min ...50-750 L/min water
    Connection G ½... G 3, ½ NPT...3 NPT
    Material aluminum/bronze, st. st.
    Max. pressure 16 bar
    Max. temperature 80 °C
    Accuracy ± 3 % FS
    Pulse output, analogue output,
  • Ultrasonic Clamp-On Flowmeter DUM
    Measuring range 0-20 m/s liquid
    Connection flange DN 15...4000
    Max.temperature 200 °C
    Accuracy ±1...3% v.m. value
  • Ultrasonic-Switch DUK-..S
    Measuring range 0,08- 20 ...2,5-630 L/min liquid
    Connection G G ½...G3 female
    Material brass
    Max. pressure 10 bar
    Max.temperature 90 °C
    Accuracy±1,5% F.S.
    Switchpoint
  • Universal Batch Controller ADI-Z
    8-digit LCD for totalizer
    4,5 (4)-digit LCD for flow,pressure, temperature
    Dimensions 96x96x105 mm, 116x116x123 mm
    Inputfrequency 0,5-2000 Hz, 4-20 mA (pressure), Pt100/3-L. (temp.)
    Steuereingänge Fernstart/-stop, TTL-Pegel
    Output 0(4)-20 mA, 0-10 V, 2 relays or 2 open collector
    1x Sensor supply5 /12 /24 VDC
  • Universal Bussystem KOBUS
    as plug-on display, 4-digit, red LED
    up to 240 sensors, BUS-length max. 1km
    for transmitters with (0)4-20 mA, 0-10 V or
    0.5..1000 Hz output and plug DIN 43 650
    software for indication, datalogger, configuration
  • Universal Indicator ADI-B..X
    Indicator bargraph
    Input current, voltage, frequency
    Housing 96x96 mm
    Option analogue -, frequency output, contacts,
    Sensor supply
    Mounting panel mounting
  • Variable Area Flowmeter / -switch KD1
    Measuring -/switching range 0,02 - 0,25 ... 10 - 100 L/h water
    2 - 20 ...150 -1.600 Nm³ /h air;
    Connection G 1/4, G 1/2, ¼ NPT, Swagelok, Ermeto
    Material st. St, glass
    Max. pressure 16 bar
    Max. temperature 0...+100 °C (0...+70°C with contact)
    Accuracy ± 1, 2 or 3 % FS
    Options contacts, up-/downstream diff.- pressure regulator
  • Variable Area Flowmeter DSV-1
    Measuring -/switching range 0,25 - 1,25 L/min ...
    10 - 130 l /min water
    ConnectionG ¼ - G 1 ¼ , ¼ - 1 ¼ NPT female
    Material brass, st. st.
    Max. pressure 10 bar
    Max. temperature 100 °C
    Accuracy ± 5% FS
  • Variable Area Flowmeter-All Metal BGN
    Measuring -/switching range
    0,5 - 5 ..13.000 -130.000 L/h water
    0,015 - 0,15 ...240 -2.400 Nm³ /h air
    Connection flange DN 15 ... DN 150, ANSI 3/4"... 6"
    Material st. st. 1.4404, PTFE-lining, Hastelloy
    Max. pressure PN 40 (16) bar
    Max. temperature 350°C
    Accuracy ±1,6% of m. value (±2% of m. value for gases)
    Options contacts, analogue output, totalizer,
    Hart, Profibus PA, ATEX
  • Variable Area Flowmeter-All Metal-Low Volume KMI
    Measuring range 0,1 - 1 L/h ... 25 - 250 L/h water
    4,5 - 45 NL/h ... 800 - 8000 NL/h air
    Connection G 1/4, G 3/8 female, compression fitting
    Material st. st.
    Max. pressure 100 bar
    Max. temperature 150 °C
    Accuracy class 4
    Option analogue output, contacts
  • Variable Area Flowmeter-Class Cone for Compressors UTS
    Measuring range 0,3-3 Nm³/h air
    Connection M18x1,5
    Material brass, st. st.
    Max. pressure 3 bar
    Max. temperature 55 °C
    Accuracy ±2,5...4% f.s.
  • Variable Area Flowmeter-Class Cone UMR/UXR
    Measuring range 5-50 ... 15-150 L/h water
    0,2-2 ... 0,3-3 Nm³/h air
    Connection G ¼ female
    Material POM-C, st. st.
    Max. pressure 6 bar
    Max. temperature 100 °C
    Accuracy ±2,5...4% f.s.
  • Variable Area Flowmeter-Class Cone URB
    Measuring range
    10-100 ... 100-1000 L/h water
    0,32-3,2 ... 3,2-32 Nm³/h air
    Connection G ½...1¼
    Material st. st.
    Max. pressure 6 bar
    Max. temperature 65 °C
    Accuracy ±2,5...4% f.s.
  • Variable Area Flowmeter-Class Cone URR
    Measuring range
    6-60 ... 300-3000 L/h water
    200-2000 ... 5000-50 000 NL/h air
    Connection G 1...1½ male, PVC-glue DN 15...25
    Material POM
    Max. pressure 6 bar
    Max. temperature 80 °C
    Accuracy ±2,5...4% f.s.
  • Variable Area Flowmeter-Class Cone UVR/UTR
    Measuring range 60-600 ... 200-2000 L/h water
    2-20 ...5-50 Nm³/h air
    Connection G 3/8, G ½ female
    Material POM-C, st. st.
    Max. pressure 6 bar
    Max. temperature 100 °C
    Accuracy ±2,5...4% f.s.
  • Variable Area Flowmeter-Class Cone-Fixed Flange URK
    Measuring range
    1-10 L/h ... 15-50 m³/h water
    0,02-0,2 ... 20-200 Nm³/h air
    Connection flange DN 15...80, ANSI ½"...3"
    Material cast iron.
    Max. pressure 10 bar
    Max. temperature 100 °C
    Accuracy ±2,5...4% f.s.
  • Variable Area Flowmeter-Class Cone-Loose Flange URL
    Measuring range
    1-10 L/h ... 0,25-2,5 m³/h water
    0,02-0,2 ... 10-100 Nm³/h air
    Connection flange DN 15...40
    Material PVC, PVDF
    Max. pressure 6 bar
    Max. temperature 100 °C
    Accuracy ±2,5...4% f.s.
  • Variable Area Flowmeter-Class Cone-Table Mounting URA
    Measuring range 10-100 L/h water
    0,2-2 Nm³/h air
    Connection G ¼ female
    Material brass, POM-C
    Max. pressure 6 bar
    Max. temperature 60 °C
    Accuracy ±2,5...4% f.s.
  • Variable Area Flowmeter-Class Cone-Thread Connection URM
    Measuring range
    0,25-2,5 L/h ... 2,5-25 m³/h water
    30-300 NL/h... 20-200 Nm³/h air
    Connection G ¼...3, DIN 11851, hose connection
    Material st. st.
    Max. pressure 6 bar
    Max. temperature 100 °C
    Accuracy ±2,5...4% f.s.
    Option contacts
  • Variable Area Flowmeter-Low Volume KDF/KDG
    Measuring range 0,25 - 2,5 ... 16 - 160 L/h water
    0,5 - 5 NL/h ... 500 - 5000 NL/h air
    Connection ¼ NPT, G ¼ female
    Material st. steel
    Max. pressure 16 bar
    Max. temperature 100 °C
    Accuracy ± 2,5% qG=50%
    Option contacts, up/downstream diff. pressure regulator
  • Variable Area Flowmeter-Plastic KSK
    Measuring range1,5 - 15 ... 100-1000 L/h water
    Connection G 3/4... G 11/2 male,
    glue-in conn. DN10..DN25
    Material trogamide, polysulfone
    Max. pressure PN 10
    Max. temperature 100 °C (60 °C with PVC-glue-in con.)
    Accuracy class 4
    Options contact, air scale
  • Variable Area Flowmeter-Plastic KSM
    Meas. -/switching range 15-150...8000-60000 L/h water
    0,8-5...100-860 m³/h air ( 0 bar rel., 20°C)
    Connection G 1 ½..G 3 1/2; glue-in - DN 25...DN 65
    Material trogamide-T, polysulfone
    Max. pressure PN 16
    Max. temperature 60 °C (trogamide), 100 °C
    (polysulfone), 140 °C (PVDF)
    Accuracy class 4
    Option reed contact
  • Variable Area Flowmeter-Plastic-Low Flow KFR
    Measuring range 0,005 -0,05...5 - 75 L/min water
    0,05 -0,5 L/min ..400 -4000 L/min air
    Connection 1/8... 1 NPT female
    Material acrylic glass
    Max. pressure 6,5 bar
    Max. temperature 65 °C
    Accuracy ± 2 ...5 % FS
  • Variable Area Flowmeter-Plastic-Low Flow KSV
    Measuring range 0,25 - 1,5 ... 10 - 80 L/h water
    20 - 80 NL/h ... 0,5 - 2,5 Nm³/h air
    Connection 1/8 NPT female
    Material polysulfone/brass, polysulfone/st. st.
    Max. pressure 6 bar
    Max. temperature 60 °C (polycarbonate); 120 °C (polysulfone)
    Accuracy +/-6 % FS
    Option needle valve
  • Variable Area Flowmeter/- switch V31
    Measuring -/switching range 10 -100 L/h ... 1.000 - 10.000 L/h water 0,3 - 3 NL/h ... 30- 300 Nm³/h air Connection
  • Variable Area Flowmeter/-switch-All Metal-Low Volume KDS/BGK
    Measuring range 0,1 - 1 L/h ... 20 - 200 L/h water
    3,0 - 30 NL/h ... 600 - 6000 NL/h air
    Connection ¼ NPT
    flange DN 15, 25 or ANSI 3/4", 1"
    Material st. st.
    Max. pressure 40 bar (64 bar) on request up to 320 bar
    Max. temperature -40...+130 °C (-25..+100°C w. contact)
    Accuracy ± 3 % FS
    Option contacts, Vor-/ oder Nachdruckregler
  • Variable Area Flowswitch-All Metal DSS
    Switching range 0,05 - 1 L/min ...10 -110 L/min water
    Connection G ¼...G 1 ¼ female
    Material brass, st. st.
    Max. pressure 250 bar (brass), 350 bar (st. st.)
    Max. temperature 100 °C
    Accuracy ± 5% FS
  • Variable Area Flowswitch-Low Volume SWK-13
    Meas.--switching range 0,2-0,8...13-24/min water
    Connection G ½ female
    Material PVC
    Max. pressure 6 bar
    Max.temperature 60 °C
    Accuracy +/- 4 % FS
    Reed contact
  • Variable Area-Flowmeter/-switch-All Metal SMV
    Measuring -/switching range0,05-1 L/min...10-250 L/min
    water
    Connection G ¼... G11/4 female
    Material brass; st. st.
    Max. pressure 250 bar (brass); 350 bar (st. st.)
    Max. temperature 100 °C
    Accuracy ± 5 % FS
    Option reed contact
  • Variable Area-Low Volume-Flow Switch KSR/SVN
    Switching range2-250 cm³/min water,
    50-6000 cm³/min N2
    Connection G ¼ female, ¼ NPT female
    Material st. st. 1.4305
    Max. pressure 16 bar
    Max. temperature 70 °C (100°C, KSR)
    Contact proximity switch or reed contact
  • Venturi Nozzle-Differential Pressure DDP
    Measuring span 1
    Connection DN 50...800,
    Material steel, st. st., PP, PVC
    Max. pressure PN 100
    Max. temperature 450 °C
    Accuracy ±1,0% of reading
  • Vicositiy Compensated Flowmeter/-switch-All Metal VKM
    Measuring -/switching range0,01- 0,07 L/min..8 - 80
    L/min
    Connection G ¼...G 1, ¼...1 NPT female
    Material brass, st. st.
    Max. pressure 250 (brass); 350 bar (st. st.)
    Max. temperature 100 °C
    Accuracy ± 4% FS
    Options reed contact, pointer indicator
  • Viscosity Compensated Flowmeter/-switch VKG
    Measuring -/switching range 0,1 - 0,45 ... 5 - 80 l /min
    Connection G ¼ ... G 1 female
    Material brass, st. st.
    Max. pressure 10 bar
    Max. temperature 100 °C
    Accuracy ± 5% FS
    Options reed contact, pointer indicator, analogue output
  • Viscosity Compensated Flowmeter/-switch-All Metal VKA
    Measuring -/switching range0,1-0,4 ... 30-100
    L/min
    Connection G ¼...G 1 female
    Material brass
    Max. pressure 250 bar
    Max. temperature 100 °C
    Accuracy ± 4% FS
    Options reed contact, pointer indicator
  • Viscosity Compensated Flowmeter/-switch-Plastic VKP
    Meas. -/switching range 2 - 20 ... 20 - 100 L/min water
    1-18...10-75 L/min oil
    Conn. G 1 male, sold. pipe, con. parts G 1/2, G 3/4
    Material polysulfone
    Max. pressure 16 bar
    Max. temperature 120 °C
    Accuracy ± 5 % FS
    Option reed contact
  • Vortex Flowmeter PWL
    Measuring range liquids 0,15 - 4,92 ...13,5-544 m³/h
    gas/vapour 3-23 ... 413-4855 m³/h
    Connection flange DN 15... DN 300
    wafer DN15...DN150
    Material st. st.
    Max. pressure PN 40
    Max. temperature 400 °C
    Accuracy liquids <0,75% of m. value (Re >20000)
    gas/vapour <1 % of m. value (Re >20000)
    analogue output, digital display
  • Vortex-Switch DVZ-..S
    Range 0,5-4,5...10-100 L/min water
    Connection G ¼...G 1, ¼...1" NPT
    Material connection
    Max. pressure 10 bar
    Max. temperature 80 °C
    Accuracy ± 2,5% v. ME
    Switchpoint

Pressure

  • Accessories for Pressure Gauges MZB
    Syphons
    Process connections
    Single and dual shut-off valves
    Shut-off cocks
    Pressure impact dampers
    Adaptors
  • All Stainless Steel Bourdon Tube Pressure Gauges for Exceptional Safety MAN-R…S
    Measuring range -1 up to 0 ... 0 up to 1000 bar
    Connection G 1/4, G ½ male, st. st.
    Housing Material st. st.
    Diameter of housing 63, 100, 160 mm
    Accuracy class 1,6 or 1,0
    Option contacts, glycerine filling
  • All Stainless Steel Bourdon Tube Pressure Gauges MAN-R
    Measuring range -1 up to 0 ... 0 up to 1000 bar
    Connection G 1/4, G ½ male, st. st.
    Housing Material st. st.
    Diameter of housing 63, 100, 160 mm
    Accuracy class 1,6 or 1,0
    Option contacts, glycerine filling
  • All Stainless Steel Pressure Transducer MAN-ZF
    Measuring range 0 up to 1 ... 0 up to 400 bar
    Connection G ½ AG, st. st.
    Housing Material st. st.
    diameter of housing 100 mm
    Accuracy class 1,0
    Analogue output option
  • Bourdon Tube Pressure Gauges MAN-R, MAN-Q
    Measuring range -1 up to 0 ... 0 up to 1000 bar
    Connection G 1/4, G ½ AG, brass
    Housing Material st. st., plastic
    Diameter of housing 63, 80, 100, 160 mm
    Accuracy class 1,6 or 1,0
    Option contacts, glycerine filling
  • Bourdon tube pressure gauges for refrigerants MAN-T
    Skale pressure and 1..3x temperature
    Measuring range -1 up to +9....-1 up to +40 bar
    Connection G 1/4st. Steel, 7/16 UNF brass
    Housing Material steell, st. St.
    Diameter of housing 63, 80, 100 mm
    Accuracy class 1,6 or 1,0
    Option contacts, glycerine filling
  • Bourdon Tube Test Pressure Gauges MAN-F
    Measuring range 0 up to 0,6 ... 0 up to 1600 bar
    Connection G ½ AG, brass, st. st.
    Housing Material steel, st. st., aluminum
    Diameter of housing 160, 250 mm
    Accuracy class 0,6; 0,25; 0,1
  • Capsule Element Pressure Gauges MAN-K
    Measuring range -25 up to 0 mbar ... -600 up to 0 mbar
    0 up to 25 mbar ... 0 up to 600 mbar
    Connection G 1/4, G ½ AG, brass
    Housing Material st. st.
    Diameter of housing 63, 80, 100, 160 mm
    Accuracy class 1,6
  • Contact options for manometers
    for housing dia. 100 mm or 160 mm
    Sliding contacts max. 4 pieces
    max. 250 Vac / 10 W /18 VA / 0,6 A
    Magnetic spring contacts max. 4 pieces
    max. 250 Vac / 30 W /50 VA / 0,6 A
    Inductive contacts acc. to DIN 19234 (NAMUR) max. 2 pieces
    Pneumatic contacts max. 2 pieces
  • Diaphragm Pressure Gauges MAN-P
    Measuring range -16...0 up to 0...250 mbar, -1...0 up to 0..40 bar
    Connection G ½ male, steel, st. st.
    Housing Material st. st.
    Diameter of housing 100, 160 mm
    Accuracy class 1,6; 2 ,5
    Option contacts, glycerine filling
  • Diaphragm, Capsule and Inline Diaphragm Seals for Pressure Gauges DRM
    Diaphragm seals, capsule seals, inline diaphragm seals for pressure gauges
  • Differential Pressure Gauge MAN-DF, -DG
    Measuring range 0 up to 0,6 bar ... 0 up to 600 bar
    Connection G ½ AG, brass, st. st.
    Housing Material steel, st. st.
    Diameter of housing 100, 160 mm
    Accuracy class 1,6
    Option glycerine filling
  • Differential Pressure Gauge PAD
    Measuring range 0...41370 kPa
    Connection ¼ NPT, ½ NPT
    Housing Material st. st.
    Accuracy ±0,075% of meas. range
  • Differential Pressure Sensor PMP
    For air or neutral gases (e.g. monitorng of filters)
    Measuring range 0 up to 500 Wc (0..50 mbar)
    Connection hose connector 6x8 mm
    Indication 4-digit LED
    Analogue output 4-20 mA, 2 relay (max. 230 Vac, 0,5 A)
    Power supply 24, 110, 230 VAC, 24 VDC
  • Differential Pressure Switch SCH-DDCM
    Switching range 4 up to 25 mbar ... 3 up to 16 bar
    Connection R 1/2" male and 1/4" female
    Housing st. st., aluminum
    Max. temperature85 °C (media)
    Micro switch, option proximity switch
  • Digital Panel Indicators DAG
    Programmable, 4-digit LED
    Dimensions 96x48, 96x24, 72x36, 48x24,
    Input temperature, frequency, current, voltage
    output 0(4)-20 mA, 0-10 V
    Options sensor supply, contacts, min/max.-memory
  • Hand-Held Pressure Measuring Device for Differential Pressure for 2 External Sensors HND-P215
    For relative pressure or absolute pressure
    Measuring range -1,999..+2,5 mbar bis 0..400 bar
    Probe External
    Accuracy ± 0,1 % FS
    Supply 9 V battery
    Holding Function, min/max. -memory,
    data logger, output 0-1 V, RS 232
  • Options for Pressure Gauges
    Our strength manometers in special versions
    Pointer marker ponter, drag pointer, min/max pointer
    Scales special scale, precision scale, customised
    Certificates calibration certificate, DKD certificate,
    cal. insignia, government approved calibration
    Throttle screws brass, stainless steel, 0.5...0.8 mm
    Others oil & fat free, silicon free, spring loaded zero-stop,
    laminated glass, vacuum safe
  • Piezoresistive Pressure Sensor front- flush SEN-32
    Front- flush membrane,
    For relative and absolute pressure
    Measuring range -1 up to 0 ... 0 up to 16 bar (relative)
    0 up to 0,25 ... 0-16 bar (absolute)
    Connection G ½ AG, st. st.
    Accuracy class 0,25 or 0,5
    Analogue output
  • Piezosistive Pressure Sensors, Internal membrane SEN-32
    Internal membrane,
    For relative pressure and absolute pressure
    Measuring range -1 up to 0 ... 0 up to 16 bar (relative)
    0 up to 0,25 ... 0 up to 16 bar (absolute)
    Connection G ¼ , G ½ AG, st. st.
    Accuracy class 0,25, 0,5 or 1,0
    Analogue output
  • Press./Diff. Press. Switch for neutr. gases SCH-HCD, SCH-DPS
    Switching range 0,2 up to 3 mbar ... 15 up to 150 mbar
    40 up to 400 mPas...500 up to 2500 mPas
    Connection G 1/8, G ¼ female, stub 6 mm
    Housing PA/POM, aluminum
    Max. temperature 60 (85) °C (media)
    Micro switch
  • Pressure Gauge Digital with Ceramic Sensor Element, Battery Powered MAN-SD
    Measuring range -1 up to 0 ... 0 up to 1600 bar
    Connection G ¼, G ½ male, ¼ NPT, ½ NPT st. st.
    Housing Material glasfibre reinforced plastic
    Diameter of housing 74 mm
    Accuracy class 0,5
    Power supply battery
    Option contact, analogue output, peak memory
  • Pressure Gauge Digital with Ceramic/Thin Film Cell PDC
    Measuring range 0 up to 2 ... 0 up to 700 bar
    Connection G ¼ male, ¼ NPT, st. st.
    Housing Material st. st.
    Diameter of housing 84 mm
    Accuracy class 0,5
    Power supply battery
  • Pressure Gauge with Membrane Diaphragm Seal MAN-RF..D
    with diaphragm seal
    Measuring range -1 up to +3 ... 0 up to 40 bar
    Connection flange 85 mm, steel
    Diaphragm 48 mm, st. steel
    Housing Material st. st., aluminium
    Diameter of housing 100 mm
    Accuracy class 1,6
    Option contacts, glycerine filling,
    remote version, vibration damping
  • Pressure Gauges Digital with Ceramic Sensor Element MAN-SF26
    Measuring range -1 up to 0 ... 0 up to 1600 bar
    Connection G ½ AG, st. st.
    Housing Material st. st.
    Diameter of housing 100 mm
    Accuracy class 0,5
    Power supply 18-30 VDC
    Option 2/4 contacts, analogue output, RS 232, peak memory, controlling of compressors, differential pressure
  • Pressure Sensor Compact Thin Film SEN-3349, -3373
    Internal membrane,
    For relative pressure
    Measuring range 0 up to 40 ... 0 up to 1000 bar
    Connection G 1/4 male, st. st.
    Accuracy class 0,5 or 1,0
    Analogue output
  • Pressure Sensor for harsh operational conditions PNK
    for diesel engines in railway or ship building
    robust Bourdon Tube for relative pressure
    Measuring range -1 up to 0 ... 0 up to 100 bar
    Connection R ¼ , R 1/2, M16x1,5, brass
    Housing sea-water resistant
    Accuracy 1,0 % FS
    Analogue output 0-20 mA or 4-20 mA
    Certificates GL
  • Pressure Sensor Piezoresistive/Thin Film -Flush Mounted SEN-3344,-3386
    Front- flush Membrane,
    For relative pressure
    Measuring range 0 up to 40 ... 0 up to 600 bar
    Connection G ½ AG, st. st.
    Accuracy class 0,25 or 0,5
    Analogue output
  • Pressure Sensors Precision Piezoresistive/Thin Film SEN-3382
    Internal membrane,
    For relative pressure
    Measuring range 0 up to 25... 0 up to 1000 bar
    Connection G ½ AG, st. st.
    Accuracy class 0,1
    Analogue output, serial interface
  • Pressure Sensors with Ceramic Element PDA
    Measuring range -1 up to 0 bar ... 0 up to 400 bar
    Connection G 1/4, G 1/2, ¼ NPT, ½ NPT
    Housing st. st.
    Max. temperature80 °C (media)
    analogue output 0(4)-20 mA, programmable,
    Semiconductor PNP/NPN, digital display
  • Pressure Sensors with Ceramic Element SEN-86 mit AUF
    Internal measuring element
    For relative pressure
    Measuring range -1 up to 0 ... 0 up to 600 bar
    Connection G ½ male, st. st.
    Accuracy class 0,5 or 1,0
    Analogue output, digital indicator
  • Pressure Switch for Aggressive Media SCH-DNM
    Switching range 15 up to 60 mbar... 16 up to 63 bar
    Connection R 1/2" male and 1/4" female
    Material of probe st. st.
    Max. temperature 85 °C (media)
    Micro switch, option proximity switch
  • Pressure Switch for Gases SCH-DGM, SCH-DWR
    Switching range 15 up to 60 mbar ... 0,2 up to 1,6 bar
    Connection R 1/2" male and 1/4" female
    Housing brass
    Max. temperature 60 °C (media)
    Micro switch
  • Pressure Switch for General Use SCH-DCM
    Switching range 1 -up to 16 mbar ... 16 up to 63 bar
    Connection R 1/2" male and 1/4" female
    Housing brass, st. st.
    Max. temperature85 °C (media)
    Micro switch, option proximity switch
  • Pressure Switch with Ceramic Element PDD
    Switching range -1 up to 0 bar ... 0 up to 400 bar
    Connection G 1/4, G 1/2, ¼ NPT, ½ NPT
    Housing st. st.
    Max. temperature80 °C (media)
    1 or 2 Semiconductor PNP/NPN,
    digital display, programmable
  • Pressure Switch with Ceramic Element/Thin Film PSC
    Switching range -1 up to +2 bar ... 0 up to 700 bar
    Connection G 1/4, G 1/2, ¼ NPT, ½ NPT
    Housing st. st.
    Max. temperature80 °C (media)
    2 Semiconductor PNP/NPN or
    1 Semiconductor PNP/NPN and analogue output
    digital display, programmable
  • Pressure Switch with Hall Sensor PDL-0
    Switching range -0,095 up to 0 bar ... 2,5 up to 25 bar
    Connection G ¼ male
    Housing brass, aluminum
    Max. temperature80 °C (media)
    N/C or N/O, p-switching
  • Pressure Switch with st. st. Sensor System SCH-DNS
    Switching range -250 up to 100 mbar ... 3 up to 16 bar
    Connection R 1/2" male and 1/4" female
    Housing aluminum (sea-water resistant)
    Max. temperature85 °C (media)
    Micro switch
  • Pressure Transmitter PAS
    Measuring range -1 up to 0 bar ... 0 up to 400 bar
    Connection G 1/4, G 1/2, ¼ NPT, ½ NPT
    Housing st. st.
    Max. temperature80 °C (media)
    analogue output 0(4)-20 mA, digital display
  • Steam Pressure Switch SCH-DWA
    Switching range 0,2 up to 1,6 bar ... 6 up to 32 bar
    Connection R 1/2" male and 1/4" female
    Housing st. st.
    Max. temperature 85 °C (media)
    Micro switch
  • U-Pipe Pressure Gauges PUM
    Measuring range 0...100 mbar
    Connection hose
  • Universal Bussystem KOBUS
    as plug-on display, 4-digit, red LED
    up to 240 sensors, BUS-length max. 1km
    for transmitters with (0)4-20 mA, 0-10 V or
    0.5..1000 Hz output and plug DIN 43 650
    software for indication, datalogger, configuration
  • Vacuum Switch SCH-VCM
    Switching range -15 -up to +6 mbar ... -1 up to +0,1 bar
    Connection R 1/2" male and 1/4" female
    Housing brass, st. st.
    Max. temperature85 °C (media)
    Micro switch, option proximity switch